Results 41 to 50 of about 239,511 (201)

Intraocular lens implantation in unilateral congenital cataract with minimal levels of persistent fetal vasculature in the first 18 months of life [PDF]

open access: yes, 2014
[PURPOSE] To describe the incidence of unilateral congenital cataract associated with minimal (ultrasonically undetectable) levels of persistent fetal vasculature in the first 18 months of the life and to report surgical methods for intraocular lens ...
Matsuo, Toshihiko
core   +1 more source

Stab Incision Glaucoma Surgery: A Modified Guarded Filtration Procedure for Primary Open Angle Glaucoma

open access: yesJournal of Ophthalmology, 2016
Purpose. To describe a modified guarded filtration surgery, stab incision glaucoma surgery (SIGS), for primary open angle glaucoma (POAG). Methods. This prospective, interventional case series included patients with POAG (IOP ≥21 mmHg with glaucomatous ...
Soosan Jacob   +5 more
doaj   +1 more source

Influence of silicone oil tamponade on self-sealing sclerotomy using 25-gauge transconjunctival sutureless vitrectomy: a retrospective comparative study [PDF]

open access: yes, 2015
Each factor and postoperative IOPs in each period of each case.
Akira Watanabe   +2 more
core   +2 more sources

Novel Combined Approach for Vision-Preserving Iridociliary Tumour Excision in a Small-Breed Dog: Contralateral Iris Excision With En-Bloc Scleral Resection. [PDF]

open access: yesVet Med Sci
• A 2.8 mm corneal paracentesis positioned opposite to the tumour location enabled fine iris scissors insertion for precise excision of tumour‐bearing iris tissue under miotic guidance with pilocarpine 2%. • A fornix‐based conjunctival peritomy 5 mm from the limbus and stepped scleral flap approach allowed circumferential deep scleral incision with 2–3 
Kang JI, Yeom JE, Park KM.
europepmc   +2 more sources

Paired opposite clear corneal incision: time-related changes of its effect and factors on which those changes depend [PDF]

open access: yes, 2017
PURPOSE To assess astigmatism induced by paired opposite clear corneal incision (OCCI) compared to single incisions and to investigate factors on which its effect depends. METHODS The study comprised 326 eyes from 326 patients.
Berta, András   +3 more
core   +3 more sources

Combined surgical intervention at terminal glaucoma

open access: yesOftalʹmologiâ, 2014
Purpose: to investigate hypotensive efficiency of new surgical intervention at terminal primary and neovascular glaucoma.Methods. Operation has been executed on 35 eyes of 35 patients with terminal primary (23 eyes) and secondary (12 eyes) neo- vascular ...
O. A. Kiseleva   +3 more
doaj   +3 more sources

Prevention of Lower Eyelid Ectropion Using Noninsional Suspension Sutures after Blepharoplasty [PDF]

open access: yesArchives of Aesthetic Plastic Surgery, 2014
Blepharoplasty is one of the most common anti-aging operations. Although rare, complications such as ectropion may occur. Thus, we introduced an operative technique to prevent ectropion of the lower lid after blepharoplasty.
So-Min Hwang   +5 more
doaj   +1 more source

Stab incision mitomycin C-assisted rapid trabeculectomy: A 'SMART' trabeculectomy alternative.

open access: yesExperimental and Therapeutic Medicine, 2020
The aim of the present study was to introduce a new modified trabeculectomy technique, stab incision mitomycin C (MMC)-assisted rapid trabeculectomy (SMART), which requires less surgical time and tissue manipulation.
C. Terzidou, A. Trivli, G. Dalianis
semanticscholar   +1 more source

Anti-Inflammatory Effect of Dexamethasone Controlled Released From Anterior Suprachoroidal Polyurethane Implants on Endotoxin-Induced Uveitis in Rats. [PDF]

open access: yes, 2016
Targeted drug delivery to the ocular tissues remains a challenge. Biodegradable intraocular implants allow prolonged controlled release of drugs directly into the eye. In this study, we evaluated an anterior suprachoroidal polyurethane implant containing
Ayres, E.   +13 more
core   +2 more sources

A flexible arched artificial photoreceptor constructed by photodeformable liquid crystal polymers and its application in vision restoration

open access: yesSmart Molecules, EarlyView.
A flexible arched artificial photoreceptor with high stability and biocompatibility was fabricated by integrating liquid crystal polymers with polyvinylidene fluoride‐trifluoroethylene. This device exhibits robust photoelectric responses under low‐intensity illumination and demonstrates efficacy in restoring visual responses in blind rats following ...
Yumeng Jiang   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy