Results 61 to 70 of about 67,845 (173)
ABSTRACT Objective To serially assess iridocorneal angle (ICA) gonioscopic morphology following phacoemulsification in dogs and to determine whether postoperative changes are associated with the development aphakic/pseudophakic glaucoma. Animals Studied Client‐owned dogs presented for cataract removal by phacoemulsification.
Steven R. Hanes +3 more
wiley +1 more source
Preliminary experience with transperitoneal single incision laparoscopic surgery adrenalectomy [PDF]
Introduction: The aim of contemporary medicine is not only a successful course of the operation, leading to improvementof the patient’s health status, but also its satisfactory cosmetic effect.
Michał Pędziwiatr +11 more
core +1 more source
cataalee/ABCB5-limbus: BCAM scRNA-seq
R code for scRNA-seq of FACS ABCB5+ limbal ...
cataalee
core +1 more source
ABSTRACT Purpose To evaluate the long‐term (> 1 year) outcomes of vision and intraocular pressure (IOP) control in dogs with glaucoma undergoing combined endoscopic cyclophotocoagulation (ECP) and Ahmed valve gonioimplantation (AVG). Methods Medical records between 2020 and 2025 were reviewed. Outcomes evaluated included IOP control (< 25 mmHg), vision
Sanskruti S. Potnis +6 more
wiley +1 more source
Colorectal Cancer Resection Via a Single Minimal Incision [PDF]
Smaller incisions may be the major reason for reduced invasiveness of laparotomy. The aim of this study was to clarify the feasibility and safety of a minimal skin incision for colorectal cancer resection.
Kondo, Masamichi +5 more
core
Gellan gum fluid gel (FG) enables controlled ocular delivery of mesenchymal stromal cell (MSC)‐derived extracellular vesicles (EV). Its shear‐thinning, solid‐liquid‐solid rheology ensures prolonged ocular retention. Sustained MSC‐EV release (∼18% in 6 hrs) supports effective EV ocular delivery.
Seyedmohammad Moosavizadeh +7 more
wiley +1 more source
Three-dimensional non-parametric method for limbus detection. [PDF]
PURPOSE:To present a novel non-parametric algorithm for detecting the position of the human eye limbus in three dimensions and a new dynamic method for measuring the full 360° visible iris boundary known as white-to-white distance along the eye ...
Ahmed Abass (6009308) +25 more
core +1 more source
Background To investigate the efficacy and safety of continuous ab interno repairing of traumatic cyclodialysis cleft in severe ocular trauma using a 30-gauge (G) needle.
Haibo Li, Jinhong Cai, Xiaofeng Li
doaj +1 more source
High glucose triggers corneal endothelial dysfunction by impairing FOXO1‐mediated ITPR1 transcription, leading to disrupted mitochondria‐associated membrane (MAM) integrity and defective ER‐to‐mitochondria Ca2+ transfer. This study develops an innovative viscous DES‐AAV‐Foxo1 delivery system with enhanced transfection efficiency. This non‐invasive gene
Hongran Zhao +10 more
wiley +1 more source
Limbus misrepresentation in parametric eye models [PDF]
Purpose To assess the axial, radial and tangential limbus position misrepresentation when parametric models are used to represent the cornea and the sclera.
Abass, A +9 more
core +1 more source

