Results 131 to 140 of about 60,967 (160)
Some of the next articles are maybe not open access.
Transmission Mode Ion/Ion Electron-Transfer Dissociation in a Linear Ion Trap
Analytical Chemistry, 2007Two related methods for effecting electron-transfer dissociation (ETD) are described that involve either the storage of analyte cations in a linear ion trap while reagent anions are transmitted through the cations or storage of the reagent anions with transmission of the analyte cations.
Xiaorong, Liang +2 more
openaire +2 more sources
Modeling of a linear ion trap with driving rectangular waveforms
Journal of Mass SpectrometryAbstractWe consider the operation of a digital linear ion trap with resonant radial ejection. A sequence of rectangular voltage pulses with a dipole resonance signal is applied to the trap electrodes. The periodic waveform is piecewise constant, has zero mean, and is determined by an asymmetry parameter : one value is taken on interval and another on ,
N V Konenkov, Alexey A Sysoev
exaly +3 more sources
Miniaturized Linear Wire Ion Trap Mass Analyzer
Analytical Chemistry, 2016We report a linear ion trap (LIT) in which the electric field is formed by fine wires held under tension and accurately positioned using holes drilled in two end plates made of plastic. The coordinates of the hole positions were optimized in simulation.
Qinghao, Wu +4 more
openaire +2 more sources
Linear Paul trap for strontium ions
Review of Scientific Instruments, 2002We demonstrate a linear radio-frequency trap for confining strontium ions that is simply constructed nearly entirely with commercial off-the-shelf components. The electrodes of this trap are spaced to allow tight radial confinement, and segmented to give tight axial confinement with minimal distortion of the radio-frequency field. The resulting secular
openaire +1 more source
A Microscale Planar Linear Ion Trap Mass Spectrometer
Journal of the American Society for Mass Spectrometry, 2018The planar linear ion trap (PLIT) is a version of the two-dimensional linear quadrupole ion trap constructed using two facing dielectric substrates on which electrodes are lithographically patterned. In this article, we present a PLIT that was successfully miniaturized from a radius of 2.5 mm to a microscale radius of 800 μm (a scaling factor of 3.125).
Trevor K, Decker +6 more
openaire +2 more sources
Positive Ion Transmission Mode Ion/Ion Reactions in a Hybrid Linear Ion Trap
Analytical Chemistry, 2004A triple quadrupole mass spectrometer capable of ion trapping experiments has been adapted for ion/ion reaction studies. The instrument is based on a commercially available linear ion trap (LIT) tandem mass spectrometer (i.e., an MDS SCIEX 2000 Q TRAP) that has been modified by mounting an atmospheric sampling glow discharge ionization (ASGDI) source ...
Jin, Wu +4 more
openaire +2 more sources
Hydrogen/deuterium exchange of myoglobin ions in a linear quadrupole ion trap
Rapid Communications in Mass Spectrometry, 2002Abstract The hydrogen/deuterium (H/D) exchange of gas‐phase ions of holo‐ and apo‐myoglobin has been studied by confining the ions in a linear quadrupole ion trap with D 2 O or CD 3 OD at a pressure of several mTorr. Apo‐myoglobin ions
Dunmin, Mao +2 more
openaire +2 more sources
Observation of sympathetically cooled 43Ca+ ions in a linear ion trap
Applied Physics B, 2011We report the observation of sympathetically cooled 43Ca+ (natural abundance 0.135%) in a linear ion trap utilizing simultaneously trapped isotope ions as coolant. We investigated different possibilities of realizing efficient sympathetic cooling and observed the peaks of the hyperfine transitions of 43Ca+ under various experimental conditions.
Y. Hashimoto +3 more
openaire +1 more source
High‐resolution excitation of ions in a low‐pressure linear ion trap
Rapid Communications in Mass Spectrometry, 2010Abstract An exploration of the parameters necessary to obtain high‐resolution excitation, using dipolar excitation, of an ion in a linear ion trap has been undertaken in this study. These parameters included ion trap pressure, excitation amplitude, excitation period, drive frequency of the ion trap, Mathieu
openaire +2 more sources
Progress on Linear Ion Trap Mercury-Ion Frequency Standard
2013Mercury-ion microwave frequency standard could achieve excellent stability and insensitivity to environment perturbations, due to its large atomic mass and Q value of clock transition spectrum line. These performances make it attractive for both ground-based and space applications.
Hao Liu +7 more