Results 251 to 260 of about 1,678,845 (291)
Some of the next articles are maybe not open access.

Holdup and flooding in air liquid mixing

The Canadian Journal of Chemical Engineering, 1968
AbstractThe amount of flowing air held up, or retained, under the surface of water and corn syrup solutions was measured in cylindrical tanks of different sizes using turbine type mixing impellers. Holdup is frequently used as an index of the effectiveness of gas‐liquid contacting in adsorption or stripping operations; it can be correlated with air ...
J. Henry Rushton, Jean‐Jacques Bmbinet
openaire   +1 more source

Scintigraphic Measurement of Liquid Holdup in Foam Fractionation Columns

Journal of Colloid and Interface Science, 2000
The profile of liquid holdup in foam fractionation columns was studied as a function of time by the use of a nuclear scintigraphic imaging technique. Sodium [(99m)Tc]pertechnetate was employed as the imaging agent and served as a marker for the amount of water present in the foam during the foam fractionation of bovine serum albumin.
, Lockwood, , Kim, , Bummer, , Jay
openaire   +2 more sources

Flooding rates and holdup in packed liquid‐liquid extraction columns

AIChE Journal, 1975
AbstractCountercurrent flow of liquids in columns packed with Raschig rings was studied with fluids having a wide range of physical properties. These results, along with data reported previously from other studies, were used to develop a correlation for predicting flooding rates in packed columns that is significantly better than previous correlations.
J. S. Watson   +3 more
openaire   +1 more source

Holdup and solvent extraction characteristics in electrostatic liquid‐liquid contactor

AIChE Journal, 1996
An unconventional contactor has been developed to aim at increasing the dispersed-phase holdup (Yamaguchi and Kanno, 1995).
Manabu Yamaguchi, Masaaki Kanno
openaire   +1 more source

Gas Holdup in Gas−Liquid Stirred Tanks

Industrial & Engineering Chemistry Research, 2010
A single-point optical probe is developed that can accurately obtain local gas holdup in a gas-liquid stirred tank across a wide range of operating pressures, temperatures, and fluids. It is found that the probe orientation to the flow in a stirred tank can cause underestimations in gas holdup if only a single probe orientation is used.
Sean G. Mueller, Milorad P. Dudukovic
openaire   +1 more source

Entrainment and holdup of gas-liquid-liquid dispersion in a downflow gas-liquid-liquid contactor

Chemical Engineering and Processing - Process Intensification, 2018
Abstract The gas-liquid-liquid downflow three-phase contactor has the advantage by dispersing gas and lighter liquid into the contactor in a continuous denser phase without any requirement of external power for gas-liquid-liquid processes like reactions and removal of organic compound dissolved in liquid.
Bharath Kumar Goshika   +1 more
openaire   +1 more source

Structured packing liquid holdup in cryogenic systems

International Journal of Refrigeration, 1997
Abstract Experimental results and a theoretical analysis are presented on structured packing liquid holdup under cryogenic conditions. The experimental tests were performed on a novel laboratory unit incorporating a gas lift pump to recirculate the cryogenic liquid in a flow visualization dewar.
R Potthoff, P Sweeney, K.R Krishnamurthy
openaire   +1 more source

Liquid distribution and holdup in the random packed column

Flow Measurement and Instrumentation, 2018
Abstract In the present work, a third-generation gamma transmission tomography system was used to evaluate the liquid distributions of a Raschig rings random packed column, at two different water flows: 2 and 6 l/min. For each water flow, the measurements were carried out at nine column heights.
A.F. Velo, D.V.S. Carvalho, M.M. Hamada
openaire   +1 more source

Liquid holdup in horizontal two-phase gas—liquid flow

Journal of Petroleum Science and Engineering, 1996
Abstract The purpose of this study was to simplify and improve the mechanistic model developed by Taitel and Dukler (1976) for estimating the liquid holdup in horizontal two-phase flow. An experimental study was first conducted to develop a data bank used for evaluation and improvement.
openaire   +1 more source

Holdup of liquid draining from inclined tubes

International Journal of Multiphase Flow, 1984
Etude analytique dans le cas de tubes dont l'angle d'inclinaison α par rapport a l'horizontale est 0°
J.J.J. Chen, P.L. Spedding
openaire   +1 more source

Home - About - Disclaimer - Privacy