Results 91 to 100 of about 12,776,601 (161)
On market-based robust load-frequency control
In a deregulated environment, Load-frequency control (LFC), as an ancillary service essential for maintaining the system reliability, acquires a fundamental role to enable power exchanges and to provide better conditions for the electricity trading ...
Bevrani, Hassan, Hiyama, Takashi
core
Optimal selection of LQR parameter using AIS for LFC in a multi-area power system
This paper proposes a method to optimize the parameter of the linear quadratic regulator (LQR) using artificial immune system (AIS) via clonal selection. The parameters of LQR utilized in this paper are the weighting matrices Q and R.
Muhammad Abdillah +5 more
doaj +1 more source
Optimasi LFC (Load Frequency Control) Pada Mikrohidro Menggunakan Metode ACO-ANFIS dan BA-ANFIS
Micro-hydro Power Plant is a small-scale power plant. Micro-hydro plants are built with enough water potential to generate electrical energy. A common problem with micro-hydro generating systems is that the output of the generator is not constant. This is caused by changes in connected loads.
Rizqi Nafiardli +3 more
openaire +1 more source
SUMMARY Ribosome assembly, a fundamental process for cellular functions, requires the precise processing of precursor rRNA (pre‐rRNA) into mature rRNAs, a transformation guided by ribosome biogenesis factors (RBFs). While this process is well characterized in yeast and mammals, the roles of RBFs in pre‐rRNA processing in plants remain poorly understood.
Mei Liu +11 more
wiley +1 more source
Nowadays power demand is increasing continuously and the biggest challenge for the power system is to provide good quality of power to the consumer under changing load conditions. When real power changes, system frequency gets affected while reactive power is dependent on variation in voltage value.
Muddasar Ali +4 more
openaire +2 more sources
The combination of Grey Wolf Optimization and Pattern Search Technique (hGWO-PS) has been introduced to optimize the parameters of two Degree of Freedom Proportional-Integral-Derivative Controller (2DOF-PID) for controlling the load frequency in Automatic Generation Control (AGC) for interconnected power system. The interconnected two area power system
V Soni, G Parmar, M Kumar, S Panda
openaire +2 more sources
Enhancing Load frequency control in power systems using Puma Optimizer – Proportional Integral Derivative Method [PDF]
Frequency instability is one of the causes of severe disturbances in the power system, including load shedding and widespread blackouts. Especially in modern power systems, frequency instability has even more serious consequences due to the propagation ...
Trung Kien Do, Thanh Long Duong
doaj
Load Frequency Control in Two Area Power System using ANFIS [PDF]
The load-frequency control (LFC) is used to restore the balance between load and generation in each control area by means of speed control. The main goal of LFC is to minimize the transient deviations and steady state error to zero in advance. This paper
VANI, M.UMA, KUMAR, T.BHARATH
core +1 more source
Frekuensi sebesar 50 Hz harus dijaga agar memberikan kualitas energi listrik yang baik. Pengaruh dari switching pada sisi beban akan membuat frekuensi energi listrik menjadi fluktuatif. Nilai frekuensi yang fluktuatif akan membuat fungsi derivatif pada kontroler Proportional Integral Derivative (PID) menjadi sangat besar, sehingga akan mempengaruhi ...
Rahmadhi Prihandono, Mochammad Rameli
openaire +3 more sources
Evaluation of different control schemes for load frequency control (LFC) in synchronous generators
In an ideal power system operation, the system frequency is always maintained constant at nominal value of 50Hz by applying the load frequency control (LFC) on the synchronous generators.
Tay Chai, Ci Hong
core