Results 131 to 140 of about 8,133 (281)
To reduce the vibration and noise of the variable hyperbolic circular arc tooth trace (VH-CATT) cylindrical gear transmission system, a method for modifying the tooth surface with an inclined milling cutter head and a parabolic cutter blade is proposed ...
Ye, Zhenhuan +3 more
core +1 more source
ABSTRACT Objectives The objective of this scoping review was to map existing literature on oral health and related care in individuals with Motor Neurone Disease (MND). Specifically, the review aimed to identify barriers and facilitators to maintaining oral hygiene, summarise available clinical guidelines and patient‐facing resources, and examine how ...
Mariam A. Khokhar +3 more
wiley +1 more source
Analysis of meshing performance of face gear with full tooth surface modification
ObjectiveTo investigate the influence of a modified tooth surface on the meshing performance of face gear pair, a full tooth surface modification method for face gear was proposed to optimize their meshing performance.MethodsFirstly, the standard tooth ...
HE Kun +3 more
doaj
Computational Tooth Root Stress Analysis of Crossed Beveloid Gears with Small Shaft Angle
It is known that tooth bending failures are directly caused by the stress state at the tooth root or fillet regions of the gear teeth. In this study, the geometric and manufacturing of the fillet and root of crossed beveloid are investigated and a ...
Cai Chao Zhu +3 more
core +1 more source
ABSTRACT Objectives The Oral Health Impact Profile (OHIP) is the most widely used instrument to measure the subjective impact of oral conditions. This study reports the shortening and psychometric evaluation of an ultra‐short version (OHIP‐7A) from the OHIP‐14 in a large national Australian population.
Brandan Khor +6 more
wiley +1 more source
ABSTRACT Objectives This laboratory study investigated the effect of two different retentive heights of Ti‐base abutments (3.5 and 5.5 mm) and crown heights (13 and 16 mm) on the load at failure and survival of monolithic zirconia implant‐supported crowns replacing a maxillary central incisor.
Esha Zahid +5 more
wiley +1 more source
ABSTRACT Objectives This cross‐sectional study primarily aimed at investigating the association between the transmucosal emergence geometry and the prevalence of peri‐implant diseases in bone‐ and tissue‐level implants (BL/TL). As secondary objectives, the association of other implant‐, prosthesis‐, and patient‐related variables with crestal bone ...
Clemens Raabe +6 more
wiley +1 more source
ABSTRACT Objective To assess the accuracy of dynamic computer‐assisted implant surgery (dCAIS) performed with and without augmented reality (AR) smart‐glasses visualization under standardized laboratory conditions. Materials and Methods A standardized typodont model with bounded and unbounded edentulous spaces was prepared to receive polyurethane ...
Arndt Guentsch, Shengtong Han
wiley +1 more source
Tooth Contact Analysis of Cycloidal Pinwheel Drive in RV Reducer of Robot
The second-stage drive of the RV reducer,cycloidal pinwheel drive is taken as the research object. By analyzing the motion relationship of the cycloidal pinwheel drive,the tooth contact analysis(TCA)model is established.
Liang Shuaifeng +4 more
doaj
Harmonic drives (HDs) with short flexspline (FS) always suffer from small meshing areas and severe stress concentration caused by large cone angles when a short FS is assembled and loaded.
Boyang Liu +7 more
core +1 more source

