Results 21 to 30 of about 670 (184)
The current necessity of the scientific and industrial community, for reduction of aircraft maintenance cost and duration, prioritizes the need for development of innovative nondestructive techniques enabling fast and reliable defect detection on ...
Spyridoula Farmaki +4 more
doaj +1 more source
Infrared Lock-in Thermography Tests with Optical Feedback
Thermography using a period light stimulation. However, the results are highly dependent on the accuracy of the stimulation source and its dynamic response.
António José Ramos Silva +3 more
doaj +1 more source
Improvement the temperature signal filtering in lock-in thermography
At present, lock-in thermography is widely used non-destructive method for defects detection. The informative images in lock-in thermography (e.g. phasegram) are obtained after temperature signal filtering of the raw data.
Stoynova Anna, Bonev Borislav
doaj +1 more source
Dynamic Thermal Contact Resistance Measurement Method Using Lock-in Thermography
This paper proposes a new thermal contact resistance measurement method using lock-in thermography. By the lock-in thermography with an infrared microscope, the dynamic temperature behavior across the contact interface was visualized in the sample side ...
Takuya Ishizaki +3 more
doaj +1 more source
Lock-in thermal tests (LTTs) are one of the best ways to detect defects in composite materials. The parameter that most affects their performance is the cycle period of the stimulation wave.
António Ramos Silva +3 more
doaj +1 more source
The success of composites in automotive, aerospace, and naval applications is mainly related to their aptitude to be tailored to obtain a final product that perfectly fulfills the design requirements.
Toscano Cinzia +3 more
doaj +1 more source
Safety Evaluation for Pure Titanium by Lock-in Infrared Thermography [PDF]
The lock-in infrared thermography has been applied to an estimation of fatigue limits at several stress ratios, i.e., R=-1, 0.05, and 0.5, for commercially pure titanium (CP-Ti JIS grade 2) at room temperature.
Matsunaga T. +3 more
doaj +1 more source
In this study, a novel nondestructive evaluation method is proposed to investigate the fiber orientation distribution of discontinuous Carbon Fiber Reinforced Plastic (CFRP).
Kohei MIYACHI +3 more
doaj +1 more source
New Developments in IR Lock-In Thermography [PDF]
Abstract Lock-in thermography based on an infrared camera has proven to be a useful tool for failure analysis of integrated circuits (ICs). This article discusses four novel technical developments of lock-in thermography. These developments are blackening the IC surface with colloidal bismuth, the synchronous undersampling technique ...
O. Breitenstein +5 more
openaire +1 more source
Laser lock-in thermography on dental inspection [PDF]
Detection of cracks in teeth and the evaluation of a dental restoration in a non-invasive way is of paramount importance in clinical practice. Common dental X-ray diagnosis is precise but causes a lot of concerns due to its ionizing radiation nature, not-so-comfortable patient experiences, as well as used-in-caution for women in pregnancy, etc.
Andrew Ngo Chun Yong +2 more
openaire +1 more source