Results 31 to 40 of about 670 (184)
A Review of Microwave Thermography Nondestructive Testing and Evaluation
Microwave thermography (MWT) has many advantages including strong penetrability, selective heating, volumetric heating, significant energy savings, uniform heating, and good thermal efficiency.
Hong Zhang +5 more
doaj +1 more source
The second-order conventional and first-order inverse magnetocaloric effects (MCEs) in Ni–Mn-based quaternary Heusler alloys have been systematically investigated by means of the lock-in thermography technique, which enables the direct measurement of the
Rajkumar Modak +4 more
doaj +1 more source
Design and Construction of an LED-Based Excitation Source for Lock-In Thermography
Active thermography is an established technique for non-destructive testing and defect localisation. For external excitation, powerful light sources are commonly used.
Patrick Dahlberg +3 more
doaj +1 more source
A sequential dual‐alignment strategy independently programs the orientation of conductive metal‐organic framework (c‐MOF) microrods and liquid crystals within a composite film. This approach creates an asymmetric bilayer structure that enables precise, multi‐responsive actuation.
Taegyun Hong +5 more
wiley +1 more source
Cooperative Goniopolar and Anomalous Nernst Transverse Thermoelectricity in Kagome Magnets
A cooperative transverse thermoelectric mechanism is realized in kagome magnets, where axis‐dependent goniopolar effects and Berry curvature‐driven anomalous Nernst coexist within the same energy window. In MgMn6Sn6, this intrinsic synergy yields a record room‐temperature transverse thermopower of 15.6 µV K−1, establishing a general strategy for high ...
Honghui Wang +12 more
wiley +1 more source
Detection of Particulate Matter With Lock‐In Thermography
ABSTRACT Ultrafine particles (UFPs), particularly black carbon (BC), are major contributors to air pollution, climate change, and health risks. Conventional quantification techniques such as Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), and Raman Spectroscopy, while effective, suffer from limitations in ...
Alina Oetsen +5 more
openaire +1 more source
Measurement of Thermal Diffusivity by Lock-in Thermography
Diffusivity is generally measured on small sample under laboratory conditions where each side of the specimen is accessible, but one-side measurement may be necessary in such applications requiring in situ inspection. Experimental results are reported applying a thermoelectric unit in contact with the sample, acting alternatively as heat source and ...
P.G. Bison, S. Marinetti, E. Grinzato
openaire +1 more source
This study combines full‐field tomography with diffraction mapping to quantify radial (ε002$\varepsilon _{002}$) and axial (ε100$\varepsilon _{100}$) lattice strain in wrinkled carbon‐fiber specimens for the first time. Radial microstrain gradients (−14.5 µεMPa$\varepsilon \mathrm{MPa}$−1) are found to signal damage‐prone zones ahead of failure, which ...
Hoang Minh Luong +7 more
wiley +1 more source
A mechanically robust, self‐healable, moisturizing, cryotolerant and adhesive GelMA hydrogel is developed by incorporating polyvinyl alcohol, acrylic acid, sodium tetraborate, and glycerol into GelMA matrix via a photoinitiated polymerization process. The hydrogel‐derived omni‐healable ionotronic pressure sensor can sensitively and consistently monitor
Zhikang Li +16 more
wiley +1 more source
Multipass lock-in thermography for the study of optical coating absorption
The development of high-power lasers requires optics with very low absorption to avoid detrimental thermal effects. In this work, we discuss our recent developments on the use of lock-in thermography to measure absorption. We apply this technique in a multipass configuration to increase the effective power on the tested samples.
Petite, Camille +6 more
openaire +3 more sources