Results 1 to 10 of about 901,680 (354)
Background Locking plates are commonly used for the fixation of comminuted, periprosthetic and osteoporotic bone fractures. These plates are secured to the bone with screws, creating a stable connection with fixed angle between the plate and the screws ...
Fatih Parmaksizoglu +2 more
doaj +4 more sources
Background:. The use of low-profile dorsal and volar locking plates for distal radial fracture surgery has improved results and lowered the complication rate compared with older plate designs. The purpose of the present randomized controlled trial was to
Morten Eikrem, MD +5 more
doaj +1 more source
Background Good clinical outcomes for locking plates as an external fixator to treat tibial fractures have been reported. However, external locking plate fixation is still generally rarely performed.
Dejan Blažević +5 more
doaj +1 more source
This study compares the novel Asia Distal Lateral Tibial Locking Plate mechanical stability to that of the current anterolateral and medial tibial plates based on finite element analysis.
Shun-Ping Wang +5 more
doaj +1 more source
Objective: The purpose of this study was to biomechanically compare cable, trochanteric grip plate, and locking plate techniques in Vancouver type AG fracture model in an in vitro test environment.
Kerim Sarıyılmaz +5 more
doaj +1 more source
Background The locking plate is a useful treatment for lateral clavicle fractures, however, there are limits to the fragment size that can be fixed.
Shingo Abe +3 more
doaj +1 more source
Functional Outcome of Intra-articular Fractures of Distal Radius: ORIF with Locking Plate vs CRPP
Background: Distal radius fractures are common, costly, and increasing in incidence. Closed reduction and percutaneous K wires fixation and ORIF with locking plate fixation are two of the mostly used surgical treatments for dorsally displaced distal ...
Bhola Shrestha +4 more
doaj +1 more source
Background: Periprosthetic femur fractures (PFF) after total hip arthroplasty, particularly Vancouver type B1 fractures, can result from a variety of factors and pose challenges for orthopedic surgeons.
Kuan-Kai Tung +5 more
doaj +1 more source
After a short historical review of locking bone plates since their inception more than a century ago to the success of the concept less than 15 years ago with today's plates, the authors present the main locking mechanisms in use. In the two broad categories - plates with fixed angulation and those with variable angulation - the screw head is locked in
Cronier, P. +5 more
openaire +2 more sources
Background The objective of this study was to determine whether one can achieve stable fixation of a two column (transverse) acetabular fracture by only fixing a single column with a locking plate and unicortical locking screws.
Bellino Michael J +5 more
doaj +1 more source

