The comparison of clinical outcomes between volar locking plate fixation and dual-plate fixation in high-energy distal radius fractures [PDF]
PurposesThe aim of this study was to compare clinical outcomes of dual-plate fixation and volar locking plate fixation in high-energy intra-articular distal radius fractures.MethodsIn this study, 168 patients with high-energy intra-articular distal ...
Lingyao Zhou +10 more
doaj +2 more sources
Comparative 3D finite element analysis of intramedullary fixation versus locking plate fixation in calcaneal fractures using micro-CT image technology [PDF]
Objective Calcaneal fracture fixation remains a challenging procedure in orthopedics, with computational tools increasingly aiding in the optimization of preoperative planning. To compare the biomechanical stability of intramedullary fixation and locking
Jiajun Wu +4 more
doaj +2 more sources
Use of the Locking Attachment Plate for Internal Fixation of Periprosthetic Femur Fractures
Introduction The locking attachment plate (LAP) can be added to a locking compression plate (LCP) to allow the fixation of locking screws bicortically around a femoral implant.
Bryce Wall MD +3 more
doaj +2 more sources
Long-term clinical and radiographic outcomes after locking plate fixation of proximal humerus fractures: a 6-year follow-up study [PDF]
Background: Locking plate fixation is widely used for the treatment of displaced proximal humerus fractures; however, robust long-term data regarding its function and late complications remain limited.
Jan Theopold, MD +3 more
doaj +2 more sources
Background: Periprosthetic femur fractures (PFF) after total hip arthroplasty, particularly Vancouver type B1 fractures, can result from a variety of factors and pose challenges for orthopedic surgeons.
Kuan-Kai Tung +5 more
doaj +1 more source
Objective: The purpose of this study was to biomechanically compare cable, trochanteric grip plate, and locking plate techniques in Vancouver type AG fracture model in an in vitro test environment.
Kerim Sarıyılmaz +5 more
doaj +1 more source
Purpose Locking plate fixation of caprine tibial segmental defects is widely utilized for translational modeling of human osteopathology, and it is a useful research model in tissue engineering and orthopedic biomaterials research due to its inherent ...
Kristin M. Bowers +13 more
doaj +1 more source
Background Good clinical outcomes for locking plates as an external fixator to treat tibial fractures have been reported. However, external locking plate fixation is still generally rarely performed.
Dejan Blažević +5 more
doaj +1 more source
Static and dynamic examination of a locking plate in various setups for the stabilization of bone shaft fractures, including periprosthetic [PDF]
Introduction: Hip and knee arthroplasty, formerly known as the “gold standard” in the treatment of articular cartilage damage, after a period of being highly popular, are changing the way they are perceived over time due to their related complications ...
Wojciech Marczyński, Andrzej Sobolewski
doaj +1 more source
Background The objective of this study was to determine whether one can achieve stable fixation of a two column (transverse) acetabular fracture by only fixing a single column with a locking plate and unicortical locking screws.
Bellino Michael J +5 more
doaj +1 more source