Results 91 to 100 of about 572,948 (211)
A parametric study of flow and heat transfer in a thermosyphon loop at specified wall temperatures
A rectangular thermosyphon loop is analyzed parametrically using a numerical technique in this study. A two-dimensional model with uniform wall temperature through heated and cooled sections of the thermosyphon is developed and the numerical results are ...
Basaran, Tahsin +1 more
core +1 more source
A novel open-loop thermosyphon heat engine driven by low-temperature waste heat is proposed for simultaneous power generation and freshwater production.
Wai Hong Lai +6 more
doaj +1 more source
Análise de termossifões que operam com mercúrio em altas temperaturas: [tese] [PDF]
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica.Os termossifões são dispositivos de condutividade térmica muito elevada, sendo capazes de transportar grandes quantidades de ...
Cunha, André Felippe Vieira da
core
One Speaker/One Poem: Jeremy Elprin on John Keats
Jeremy Elprin (Université de Caen Normandie) will be presenting John Keats's poem "On First Looking into Chapman's Homer". The session will be moderated by Marc Porée You can follow the presentation on YouTube via this link (or via Zoom for the LOOP ...
The LOOP team
core
Fabrication and visualization of a loop thermosyphon
碩士本文為研製與測試可視化之迴路式虹吸熱管,其蒸發器內部為直徑35mm、長19mm,汽相流道外徑9mm、液相流道外徑6mm,管壁厚度各為1.5mm,冷凝器管路內直徑6mm、長81mm,加熱面積為31mm x 31mm。 迴路式虹吸熱管於內部壓力7 Torr(mmHg)下充填20%之去離子水,銅粉燒結毛細結構之直徑為35mm並製作成三種不同之厚度分別為0.4mm、0.7mm、1.0mm,銅粉平均粒徑與孔隙率分別為100μm及51%。輸入功率逐步由18W增加至236W ...
黃俊賢; Huang, Chun-hsien
core +1 more source
State Feedback Control of a Single-Loop Thermosyphon System Via a Quotient Controller [PDF]
The objective of this work is to design a quotient controller to stabilize a chaotic flow in a single loop thermosyphon system with a high heat index. The thermosyphon loop is heated from below and cooled from above, which causes time-dependent chaotic ...
Tanner, Jonathan S.
core
International audienceThis paper presents an analytical model for a thermosyphon loop developed for cooling air inside a telecommunication cabinet. The proposed model is based on the combination of thermal and hydraulic management of two-phase flow in ...
Chehade, Ali +3 more
core +1 more source
Experimental Research on a Cooling System with Two Phase Closed Thermosyphon Loop for a DAM
Two phase thermosyphon loop has a good potential of application in cooling of electronic equipment with high power source because of its relatively high efficiency of heat dissipation performance. To solve the cooling problem of a DAM with four channels,
Zhang Genxuan +3 more
doaj
Decentralized Disturbance Rejection Control of Triangularly Coupled Loop Thermosyphon System
In this paper, we investigate the stability of a triangularly coupled triple-loop thermosyphon system with momentum and heat exchange at the coupling point as well as the existence of disturbances.
Novel Kumar Dey, Yan Wu
doaj +1 more source