Results 81 to 90 of about 572,948 (211)
Experimental investigation on controllable loop thermosyphon with a reservoir
Abstract The controllable loop thermosyphons (CLTs) can be widely applied in temperature control applications, such as cool-storage refrigerators powered by solar energy or electricity with the TOU (time of use) price. However, the performance of the CLT requires further optimization.
Cao, Jingyu +5 more
openaire +3 more sources
Application of a two-phase thermosyphon loop with minichannels and a minipump in computer cooling [PDF]
This paper focuses on the computer cooling capacity using the thermosyphon loop with minichannels and minipump. The one-dimensional separate model of two-phase flow and heat transfer in a closed thermosyphon loop with minichannels and minipump has been ...
Mikielewicz, J., Bieliński, H.
core +1 more source
Wall shape optimization for a thermosyphon loop featuring corrugated pipes
In the present paper we address the problem of optimal wall-shape design of a single phase laminar thermosyphon loop. The model takes the buoyancy forces into account via the Boussinesq approximation.
J A M Dam, R M M Mattheij
core
Wind-driven device for cooling permafrost. [PDF]
Qin Y, Wang T, Yuan W.
europepmc +1 more source
Multiport mini-channel thermosyphon with hydraulic diameters less than 2 mm undergoes a severe entrainment problem both in vapor and liquid regions, impeding the flow and affecting the performance characteristics. To address this issue, a novel multiport
Jaya Antony Perinba Selvin Raj +6 more
doaj +1 more source
Heat transfer enhancement of a loop thermosyphon with a hydrophobic spot-coated surface
Heat transfer characteristic of a closed two-phase thermosyphon with enhanced boiling surface is studied and compared with that of a copper mirror surface.
Hongbin HE +6 more
doaj +1 more source
Polymer and Composite Materials in Two-Phase Passive Thermal Management Systems: A Review. [PDF]
Alqahtani AA, Bertola V.
europepmc +1 more source
Análise de um secador de ervas finas assistido por termossifões [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2014.Neste trabalho propõe-se estudar a secagem de ervas finas em dois tipos diferentes de secadores ...
Rodríguez Cisterna, Luis Hernán
core
INVESTIGATION OF THERMOSYPHON LOOP PERFORMANCE IN DOUBLE-CYCLE DISTILLATION HEAT PUMP SYSTEM
The performance of a thermosyphon loop in a double – cycle distillation heat pump system, utilizing water as a working fluid and finned tube heat exchangers for evaporator and condenser, has been investigated.
Mohammed A. Hussien
doaj
Fan failure of loop thermosyphon systems (LTS) is a major factor affecting thermal safety of data centers. This paper develops a distributed-parameter model to accurately predict the overall and local heat transfer performance of a loop thermosyphon (the
Sikai Zou, Quan Zhang, Chang Yue
doaj +1 more source