Results 51 to 60 of about 238,857 (343)

Single‐molecule DNA flow‐stretch assays for high‐throughput DNA–protein interaction studies

open access: yesFEBS Open Bio, EarlyView.
We describe an optimised single‐molecule DNA flow‐stretch assay that visualises DNA–protein interactions in real time. Linear DNA fragments are tethered to a surface and stretched by buffer flow for fluorescence imaging. Using λ and φX174 DNA, this protocol enhances reproducibility and accessibility, providing a versatile approach for studying diverse ...
Ayush Kumar Ganguli   +8 more
wiley   +1 more source

Gm-boosted Flat Gain UWB Low Noise Amplifier with Noise Cancellation

open access: yesChemical Engineering Transactions, 2015
This paper presents a high power gain (S21) and low Noise Figure (NF) 3.1-10.6 GHz common gate (CG) CMOS ultra wideband (UWB) low noise amplifier (LNA) using active gm-boosted technology, T-match input network, self-body-bias, current reused and noise ...
X.R. Zhao   +4 more
doaj   +1 more source

Low-Noise Amplification of a Continuous Variable Quantum State

open access: yes, 2009
We present an experimental realization of a low-noise, phase-insensitive optical amplifier using a four-wave mixing interaction in hot Rb vapor. Performance near the quantum limit for a range of amplifier gains, including near unity, can be achieved ...
Boyer, Vincent   +5 more
core   +1 more source

100 K uncooled GaAs mesfet amplifier as paramp replacement [PDF]

open access: yes, 1978
The characterisation, design and realisation of a low noise GaAs m.e.s.f.e.t. amplifier to replace a narrow band parametric amplifier at 1.7 GHz is described.
de los Reyes, Elías
core   +2 more sources

A Systematic Comparison of Alpha‐Synuclein Seed Amplification Assays for Increasing Reproducibility

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Seed amplification assays (SAAs) enable ultrasensitive detection of misfolded α‐synuclein across biofluids and tissues. Yet, heterogeneity in protocols limits cross‐study comparability and clinical translation. Here, we review α‐synuclein SAA methods and their performance across various biological matrices.
Manuela Amaral‐do‐Nascimento   +3 more
wiley   +1 more source

Field-effect transistor improves electrometer amplifier [PDF]

open access: yes, 1964
An electrometer amplifier uses a field effect transistor to measure currents of low amperage. The circuit, developed as an ac amplifier, is used with an external filter which limits bandwidth to achieve optimum noise ...
Munoz, R.
core   +1 more source

A Robust Adaptive One‐Sample‐Ahead Preview Super‐Twisting Sliding Mode Controller

open access: yesInternational Journal of Adaptive Control and Signal Processing, EarlyView.
Block Diagram of the Robust Adaptive One‐Sample‐Ahead Preview Super‐Twisting Sliding Mode Controller. ABSTRACT This article introduces a discrete‐time robust adaptive one‐sample‐ahead preview super‐twisting sliding mode controller. A stability analysis of the controller by Lyapunov criteria is developed to demonstrate its robustness in handling both ...
Guilherme Vieira Hollweg   +5 more
wiley   +1 more source

Power-to-Noise Optimization in the Design of Neural Recording Amplifier Based on Current Scaling, Source Degeneration Resistor, and Current Reuse

open access: yesBiosensors
This article presents the design of a low-power, low-noise neural signal amplifier for neural recording. The structure reduces the current consumption of the amplifier through current scaling technology and lowers the input-referred noise of the ...
Zhen Wang   +5 more
doaj   +1 more source

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

open access: yesAdvanced Engineering Materials, EarlyView.
Focused ion beam (FIB) milling is a common tool for nanoscale material processing, however irradiation damage, redeposition, and contamination can occur. We use several characterization tools to show FIB‐induced effects beyond 1 mm from the milled area.
Thomas W. Pfeifer   +3 more
wiley   +1 more source

Low-loss meta-atom for improved resonance response

open access: yesAIP Advances, 2012
Measurements of a meta-atom integrated with a low noise amplifier into the split-ring resonator are presented. A comparison is made between baseline meta-atoms and one integrated with a GaAs low noise amplifier.
Derrick Langley   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy