Results 251 to 260 of about 37,424 (285)
Some of the next articles are maybe not open access.

Low Voltage Ride Through of Voltage Source Converters With Droop Control

2021 IEEE 16th Conference on Industrial Electronics and Applications (ICIEA), 2021
In this paper, the transient stability of droop-controlled voltage source converters (VSCs) is studied. Firstly, according to the rotor motion equation of a synchronous generator (SG), the large-signal model of VSCs is established. On this basis, the mechanism of transient instability of the converter during short-circuit fault is revealed through the ...
Xing Zhang   +5 more
openaire   +1 more source

Mode switching DFIG for low voltage ride through

8th International Conference on Power Electronics - ECCE Asia, 2011
With the rapid development of world-wide wind energy generation using doubly fed induction generations (DFIGs), low voltage ride through (LVRT) has become a great concern. This paper focuses on a unique topology of DFIG called IG connection mode to help the DFIG ride through grid faults smoothly.
Wei, Feng, Vilathgamuwa, Don
openaire   +2 more sources

Comparison of some low voltage ride-through strategies

IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society, 2017
PV system integration with power grid has many challenges. One of these challenges, the disconnection of PV inverters from the grid under grid faults; these disconnections lead to a stability problem in larger scale of PV power plant. This paper is focused on the comparison of some Low voltage ride-through strategies.
Elshiekh K. Mohammedsaeed, Ke Jia
openaire   +1 more source

Low voltage fault ride through control in MMC-HVDC

2017 IEEE 26th International Symposium on Industrial Electronics (ISIE), 2017
Modular multilevel converters (MMCs) are the latest converter topology for the high voltage high power applications like the high voltage dc (HVDC) transmission. This paper presents the response of an MMC-HVDC converter during grid faults. Recent grid code requirements specify reactive current injection during low voltage fault conditions and negative ...
Chaudhary, Sanjay   +3 more
  +5 more sources

Low-Voltage-Ride-Through-Assistenzsystem für dezentrale Erzeugungseinheiten

e & i Elektrotechnik und Informationstechnik, 2014
Wahrend eines Kurzschlusses im Netz nahe einem Synchrongenerator kommt es aufgrund einer verminderten Leistungsabgabe wahrend des Fehlers zu einer Beschleunigung des Rotors. Dies kann zu unerwunscht hohen Polradpendelungen bis hin zum Verlust des Synchronismus des Generators fuhren.
Norbert Essl, Herwig Renner
openaire   +1 more source

Low Voltage Ride Through Characteristics of Grid Forming inverters

2020 21st International Scientific Conference on Electric Power Engineering (EPE), 2020
With the certainty of the high share of power electronics in power grid, algorithms for various grid forming inverters have emerged in academia. Due to the grid synchronization strategy of the grid forming inverter is completely different from the current grid following inverters, its dynamic characteristics during grid faults are also different.
Ziqian Zhang   +4 more
openaire   +1 more source

Low voltage ride through(LVRT) research of DFIG

2013 25th Chinese Control and Decision Conference (CCDC), 2013
Nowadays Doubly Fed Induction Generator (DFIG) is used in variable speed wind power plants extensively. Doubly fed induction generator (DFIG) has many advantages such as low cost, reduced losses with an improved efficiency, variable speed operation and improved active and reactive power control capabilities.
Li Lianbing, Zhang Peng
openaire   +1 more source

Low-voltage ride-through simulation for microgrid systems

2017 IEEE International Conference on Electro Information Technology (EIT), 2017
In contrast to the previous generation of power grid codes, recent standards require that distributed energy resources (DERs) provide low-voltage ride-through (LVRT) capabilities during grid faults. Consequently, the high penetration of DERs in today's power system requires an efficient method of controlling the active and reactive power of those ...
Elham Foruzan   +2 more
openaire   +1 more source

Voltage rise mitigation and low voltage ride through capabilities for grid-connected low voltage microgrids

2017 19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe), 2017
The total real power injected by distributed renewable energy sources (RES) in the low voltage (LV) grids can cause voltage rise effects during light load scenarios. Integrating RES in microgrid architectures can result in improved power quality of the electrical grid, by avoiding the voltage rise effect from occurring and also by providing ancillary ...
Alexander Micallef   +1 more
openaire   +1 more source

Effect of low voltage ride through (LVRT) characteristic on voltage stability

IEEE Power Engineering Society General Meeting, 2005, 2005
The number of wind installations has grown worldwide at unprecedented rates in recent years. As well, the average size of the installations has increased due to the advent of larger capacity machine, variable speed technology, and an increasing number of off-shore sites.
C. Abbey, G. Joos
openaire   +1 more source

Home - About - Disclaimer - Privacy