Results 231 to 240 of about 2,947 (265)
Some of the next articles are maybe not open access.
Low-Voltage Ride-Through Remote Testing Method for Offshore Wind Turbines
IEEE Transactions on Instrumentation and Measurement, 2020Grid-connected wind turbines (WTs) are required to have low-voltage ride-through (LVRT) capability. On-site LVRT test is a convincing certificating method. To tackle the limited accessibility and harsh conditions of on-site test for offshore WTs, this paper proposes a remote testing method, which places the testing device on shore to produce the ...
Zimin Jiang, Yutian Liu 0002
openaire +1 more source
Low Voltage Ride-through of PV System Based on APFF
2018 2nd IEEE Conference on Energy Internet and Energy System Integration (EI2), 2018Aiming at problems of two-stage photovoltaic(PV) grid-connected system including inverter overcurrent and large fluctuation of DC-side capacitor voltage when the grid voltage drops, a low voltage ride-through optimization control strategy based on active power feed forward(APFF) mode is proposed.
Yan Li +5 more
openaire +1 more source
Low-voltage Ride-through Capability Characterization of Wind Farms
Electric Power Components and Systems, 2012Abstract This article characterizes low-voltage ride-through capability of wind farms. Critical clearing time has been used in the literature as a measure of the transient stability of induction generators and, hence, an indication for low-voltage ride-through capability of single wind turbine generators.
A. S. Awad +2 more
openaire +1 more source
Comparison of several Low Voltage Ride Through Attached Equipment
2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP), 2019The power plant auxiliary drive system will work abnormally or even trip due to frequency converter voltage drops, which might be caused by transient state process of auxiliary power system or the external grid. Low voltage ride through (LVRT) is an effective way to solve the above problem.
Donghui Wang +5 more
openaire +1 more source
The current control of PV inverter for low voltage ride through
2012 15th International Power Electronics and Motion Control Conference (EPE/PEMC), 2012The objective of this paper is to propose a maximum current amplitude control (MCAC) for the Photovoltaic (PV) power system with the low-voltage ride-through (LVRT) behaviour. The proposed MCAC strategy can generate the demanded active and reactive power depending on the output power condition of the PV array and the power rating of the grid-tied ...
Yong-Sih Wu +5 more
openaire +1 more source
Improving Microgrid Low-Voltage Ride-Through Capacity Using Neural Control
IEEE Systems Journal, 2020In this article, a neural sliding-mode linearization controller is proposed to regulate the generated active and reactive power for each distributed energy resource in a microgrid. The developed controller is based on recurrent high-order neural network identification, trained online with an extended Kalman filter learning algorithm.
Larbi Djilali +4 more
openaire +1 more source
A rapid voltage detection method for low voltage ride through under distorted voltage conditions
2015 IEEE International Conference on Mechatronics and Automation (ICMA), 2015This paper deals with a novel voltage detection method for low voltage ride through under distorted voltage conditions. According to the new Grid Codes, the photovoltaic (PV) system should keep connected with the grid and inject the acquired reactive power as soon as possible when the grid voltage sags.
Liang Zhou +3 more
openaire +1 more source
A study of low voltage ride-through capability for offshore wind power plant
2011 IEEE International Conference on Smart Grid Communications (SmartGridComm), 2011Electric power produced by renewable energy resources has been increased drastically, where the wind generation plays the dominant role in supplying green energy. Due to the limited available sites for onshore wind farms, offshore wind generation has attracted much attention in recent years.
H. M. Huang +4 more
openaire +1 more source
Improvement low-voltage ride-through control of DFIG during grid faults
2014 International Conference on Multimedia Computing and Systems (ICMCS), 2014This paper presents an improvement control to enhance Low-voltage Ride-through (LVRT) capability of a doubly fed induction generator (DFIG). The DFIG is very sensitive to grid fault. When voltage dip occurs, there are overvoltage and a transition of the current in rotor winding.
Tariq Riouch, Rachid El Bachtiri
openaire +1 more source
Low voltage ride through capability of fuel cell generation system connected to low voltage network
2011 IEEE Conference on Clean Energy and Technology (CET), 2011New grid code is expected to require distributed generation units operating parallel with the low voltage grid to ride through low voltage event and at the same time injecting reactive current into the grid. The paper discusses and highlights the problems that could arise and explores the solutions to mitigate these problems.
Wanik, Mohd Zamri Che +3 more
openaire +2 more sources