Results 91 to 100 of about 1,238 (203)

An Overcurrent Suppression Strategy for Distributed Photovoltaic Inverters Under Unbalanced Faults Based on Adaptive Linear Active Disturbance Rejection Control

open access: yesIET Smart Grid, Volume 9, Issue 1, January/December 2026.
After distributed photovoltaic (PV) systems are connected to the distribution network, the overcurrent problem caused by transient faults instantaneously threatens the safety of PV inverters and other equipment. This paper proposes a comprehensive control method that combines active‐loop adaptive linear active disturbance rejection control (A‐LADRC ...
Dandan Zhu   +6 more
wiley   +1 more source

Voltage sag assessment method considering low-voltage ride-through of inverter-interfaced distributed generators

open access: yesInternational Journal of Electrical Power & Energy Systems
Voltage sags often disrupt the normal functioning of sensitive equipment and distributed generators (DGs), making voltage sag mitigation based on corresponding assessments crucial. Voltage sag characteristics, including voltage magnitude and sag duration,
Xian-yong Xiao   +3 more
doaj   +1 more source

Experimental Verification of the Performance of a Nonlinear Regulator Based on Genetic Algorithms in Improving the Power Quality of DFIG

open access: yesInternational Transactions on Electrical Energy Systems, Volume 2026, Issue 1, 2026.
This experimental work investigates the energy control of the doubly fed induction generator. The energy control is performed using a direct power control based on a fractional‐order proportional‐integral (FOPI) regulator. The PI regulator parameters are calculated using a genetic algorithm. The use of this strategy ensures stable operation of the DFIG,
Habib Benbouhenni   +6 more
wiley   +1 more source

Evaluation of low voltage ride-through capability of synchronous generator connected to a grid [PDF]

open access: yes, 2015
The grid compliance of generators has been largely focused on wind power generators in literatures. With the increase in installation of distributed power systems, the dynamic performance of governor controlled prime mover driven generators might be ...
Viknash Shagar, AU (15843791)   +4 more
core  

Comparative analysis of metaheuristic algorithms-based control for enhancing low voltage ride through in grid-connected photovoltaic systems

open access: yesAin Shams Engineering Journal
This paper aims to investigate the improvement of the low voltage ride-through (LVRT) in grid-connected photovoltaic (PV) systems by applying the Gold Rush Optimization (GRO) algorithm to design system PI controllers.
Yasmin GH. Mousa   +5 more
doaj   +1 more source

Investigating low voltage ride through capability on wind farm by using static synchronus compensator (STATCOM) application [PDF]

open access: yes, 2012
As an alternative to traditional fossil fuel extracted energy, wind energy has been acknowledged as one of the most important sources of renewable energies in the world.
Forest, Zack
core   +1 more source

Power Quality Knowledge Application for Low Voltage Ride Through Studies of Wind Turbine Generator [PDF]

open access: yes, 2019
Low voltage ride through (LVRT) of wind turbines is an important grid integration issue and the subject of many studies. However, in many such studies, the voltage dip waveforms used to test the performance of LVRT methods are not the one that can occur ...
Azam Bagheri   +7 more
core   +1 more source

Low voltage ride through capability of a 5 kW grid-tied solar inverter [PDF]

open access: yes, 2010
— Distributed power generation systems (DPGS) such as wind and solar become more and more widely spread. As a consequence grid operating companies demand system services.
Friedrich W. Fuchs   +3 more
core   +1 more source

Comprehensive Overview of Low Voltage Ride Through Methods of Grid Integrated Wind Generator

open access: yesIEEE Access, 2019
The wind power generation is a rapidly growing grid integrated renewable energy (RE) technology with an installed capacity of 539.291 GW. The capability of the wind energy conversion system (WECS) to remain integrated into the utility network in the case
Om Prakash Mahela   +3 more
doaj   +1 more source

A Novel Low Voltage Ride-Through Technique of Three-Phase Grid-Connected Inverters Based on a Nonlinear Phase-Locked Loop

open access: yesIEEE Access, 2019
In this paper, a novel low voltage ride-through (LVRT) technique for three-phase grid-connected inverters is proposed. The proposed technique consists of two parts: a nonlinear phase locked loop based on complex-coefficient filters (NLCCF-PLL) and an ...
Guangyu Sun   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy