Results 21 to 30 of about 465 (163)

The transient instability mechanism and stability‐enhanced LVRT control for VSC riding‐through severe grid voltage sag

open access: yesIET Renewable Power Generation, 2023
As the grid‐connected interface device of wind and photovoltaic power generation, the voltage source converter (VSC) must pass the low voltage ride‐through (LVRT) test. However, existing literature demonstrates that under weak grid conditions, there is a
Huiqiang Sun   +6 more
doaj   +1 more source

Low-Voltage Ride Through Strategy for MMC With Y₀/Y₀ Arrangement Transformer Under Single-Line-to-Ground Fault

open access: yesIEEE Access, 2021
In the offshore wind farm high-voltage direct-current (HVDC) system, the power delivery capability of the onshore modular multilevel converter (MMC) decreases severely under grid fault, which makes the DC-bus voltage increase rapidly and threatens the ...
Xiaohe Wang   +4 more
doaj   +1 more source

Enabling LVRT Compliance of Electrolyzer Systems Using Energy Storage Technologies

open access: yesBatteries, 2023
This paper presents a comprehensive techno-economic analysis of different energy storage systems (ESSs) in providing low-voltage ride-through (LVRT) support for power electronics-based electrolyzer systems.
Pankaj Saha   +4 more
doaj   +1 more source

Low voltage ride through capability for resilient electrical distribution system integrated with renewable energy resources

open access: yesEnergy Reports, 2023
It is evident that renewable energy sources (RES), will soon be considered as primary energy source in electrical networks. However, the increased penetration of RES along with the variable charging profile of electric vehicles in the distribution grid ...
Monika Yadav   +2 more
doaj   +1 more source

LVRT Control Strategy For DC Microgrids Considering the Characteristics of PV/Storage/Load

open access: yesZhongguo dianli, 2019
Low voltage ride-through (LVRT) of grid-connected DC microgrid has been driving academic attentions. Firstly, the structure and operation principle of DC microgrids are developed to obtain the analytical expression of DC bus voltage.
Yan LI   +4 more
doaj   +1 more source

Fault Ride-Through Control Strategy for Variable Speed Pumped Storage Unit with Full-Size Converter

open access: yesApplied Sciences
Fault ride-through is a prerequisite for ensuring continuous operation of a variable-speed pumped storage unit with a full-size converter (FSC-VSPU) and providing support for the renewable energy and power grid.
Huabo Shi   +7 more
doaj   +1 more source

Augmentation of Low Voltage Ride through (LVRT) Capability using ANN based electric spring for a Grid-tied Wind Energy Conversion System

open access: yesIOP Conference Series: Materials Science and Engineering, 2021
Abstract Electric Spring (ES) is an innovative approach for distributed voltage control (DVC) whereas at the same time accomplishing nominal demand-side management (DSM) technique for continuously varying renewable energy sources. In order to demonstrate the efficiency of ES when deployed in enormous quantities across the grid-connected ...
M.D. Udayakumar   +4 more
openaire   +1 more source

Low-Voltage Ride-Through Techniques in DFIG-Based Wind Turbines: A Review

open access: yesApplied Sciences, 2020
In recent years, considerable advances were made in wind power generation. The growing penetration of wind power makes it necessary for wind turbines to maintain continuous operation during voltage dips, which is stated as the low-voltage ride-through ...
Boyu Qin   +4 more
doaj   +1 more source

Review of low voltage ride-through technology of doubly-fed induction generator

open access: yesThe Journal of Engineering, 2019
In recent years, with the increasing of wind power development, the demand for low voltage ride-through (LVRT) technology was proposed to ensure the safe and reliable operation of the power system.
Lele Niu   +4 more
doaj   +1 more source

Comparison of Fuzzy Logic and PID Control in H‐Bridge Inverter: Performance Analysis and Response Optimization

open access: yesEngineering Reports, Volume 8, Issue 2, February 2026.
Under identical conditions, we benchmark PID against Fuzzy‐Logic control for a single‐phase H‐bridge inverter. FLC achieves faster rise/settling with lower THD and better disturbance rejection than tuned PID while requiring explicit rule design—offering a reproducible baseline and deployment guidance for power‐quality‐constrained inverter applications.
Baraa Taha   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy