Results 31 to 40 of about 7,397 (245)
In this paper, a power compensator using supercapacitors in parallel to protect grid-connected devices connected to the distributed power supply in the case of a low-voltage ride-through (LVRT) situation in designed, and a grid-connected device control method with improved responsiveness is proposed.
Mi-na Kim +3 more
openaire +1 more source
With an increasing share in energy production, wind turbines have to fulfill strict grid requirements to support the grid in case of discontinuities. Here LVRT (Low Voltage Ride Through) compliance is one essential part, where the turbine has to stay ...
Mathias Arbeiter +2 more
doaj +1 more source
ENHANCING LOW VOLTAGE RIDE THROUGH CAPABILITY IN UTILITY GRID CONNECTED SINGLE PHASE SOLAR PHOTOVOLTAIC SYSTEM [PDF]
The steady rise in utility grid penetration of single phase solar photovoltaic system has contributed to the mandatory requirement of Low Voltage Ridethrough (LVRT) capability. LVRT capability provides stable grid integration during transient conditions.
RINI ANN JERIN A. +3 more
doaj
As the grid‐connected interface device of wind and photovoltaic power generation, the voltage source converter (VSC) must pass the low voltage ride‐through (LVRT) test. However, existing literature demonstrates that under weak grid conditions, there is a
Huiqiang Sun +6 more
doaj +1 more source
In the offshore wind farm high-voltage direct-current (HVDC) system, the power delivery capability of the onshore modular multilevel converter (MMC) decreases severely under grid fault, which makes the DC-bus voltage increase rapidly and threatens the ...
Xiaohe Wang +4 more
doaj +1 more source
PI-based controller for low-power distributed inverters to maximise reactive current injection while avoiding over voltage during voltage sags [PDF]
This paper is a postprint of a paper submitted to and accepted for publication in IET Power Electronics and is subject to Institution of Engineering and Technology Copyright.
Camacho Santiago, Antonio +4 more
core +2 more sources
Enabling LVRT Compliance of Electrolyzer Systems Using Energy Storage Technologies
This paper presents a comprehensive techno-economic analysis of different energy storage systems (ESSs) in providing low-voltage ride-through (LVRT) support for power electronics-based electrolyzer systems.
Pankaj Saha +4 more
doaj +1 more source
Power control strategies during voltage sags according to Spanish grid code [PDF]
In order to connect any power converters into the grid there are some grid requirements to insure the safe operation of the grid. So, the control of the converters especially during abnormal condition e.g. during voltage sags is
Bakkar, Mostafa +4 more
core +1 more source
Given the “carbon neutralization and carbon peak” policy, enhancing the low voltage ride-through (LVRT) capability of wind farms has become a current demand to ensure the safe and stable operation of power systems in the context of a possible severe ...
Botong Li +5 more
semanticscholar +1 more source
LVRT Control Strategy For DC Microgrids Considering the Characteristics of PV/Storage/Load
Low voltage ride-through (LVRT) of grid-connected DC microgrid has been driving academic attentions. Firstly, the structure and operation principle of DC microgrids are developed to obtain the analytical expression of DC bus voltage.
Yan LI +4 more
doaj +1 more source

