Results 1 to 10 of about 2,872 (262)

PMSM low voltage ride through based on Coordinated Control Strategy [PDF]

open access: yesE3S Web of Conferences, 2021
Based on the analysis of the operation characteristics of the fault of direct-drive permanent magnet wind turbine and the existing protection strategies, in order to improve the low-voltage operation capability of direct-drive permanent magnet wind ...
Zhaopeng Zhang, Dongnan Suo
doaj   +2 more sources

Low-voltage ride through of multi-port power electronic transformer

open access: yesiEnergy, 2022
A low-voltage ride-through (LVRT) control strategy for the multi-port power electronic transformer (PET) based on power co-regulation is proposed.
Wusong Wen   +3 more
doaj   +2 more sources

Enhancement of Low Voltage Ride Through Capability of Doubly Fed Induction Generator Based Wind Turbine Using Fuzzy Logic Controller [PDF]

open access: yesE3S Web of Conferences, 2021
Combined impact of environmental issues and policies of utilities has led to generation of clean and sustainable energy. Solar and wind energies are prominent and can provide bulk amount of electrical energy.
Manohar G   +2 more
doaj   +1 more source

Implementation Strategy of Test Facility Based on Auto-Transformer for LVRT/HVRT Evaluation of Large-Scale Wind Turbine

open access: yesEnergies, 2023
In accordance with South Korea’s recent 2030 Carbon Neutral Plan, an 8GW offshore wind farm is planned for construction in the South-west Sea. Therefore, it is expected that large-scale wind turbines will be installed, and these turbines must operate ...
Byungki Kim   +3 more
doaj   +1 more source

Low voltage ride-through of single-phase transformerless photovoltaic inverters [PDF]

open access: yes2013 IEEE Energy Conversion Congress and Exposition, 2013
Transformerless photovoltaic (PV) inverters are going to be more widely adopted in order to achieve high efficiency, as the penetration level of PV systems is continuously booming. However, problems may arise in highly PV-integrated distribution systems. For example, a sudden stoppage of all PV systems due to anti-islanding protection may contribute to
Yang, Yongheng   +2 more
openaire   +4 more sources

Low voltage and high voltage ride‐through technologies for doubly fed induction generator system: Comprehensive review and future trends

open access: yesIET Renewable Power Generation, 2021
The advantages, such as the mature control method, less volume of the converter and generator, make the doubly fed induction generator system prevalent in the wind power industry.
Zakiud Din   +4 more
doaj   +1 more source

Over-current low voltage ride-through operation of grid-connected converters based on thermal analysis

open access: yesPower Electronic Devices and Components, 2023
The grid-connected converters are becoming an important role in modern power grid. The grid codes have been proposed for the operation of grid-connected converters.
Jiashi Wang   +4 more
doaj   +1 more source

A low voltage ride-through control method of IIDG considering multiple control targets [PDF]

open access: yes电力工程技术, 2022
There are some disadvantages in existing inverter-interfaced distributed generators (IIDG) low voltage ride-through control methods,such as unsatisfactory voltage support effects,single control objectives,and the risk of over-limiting the output current.
HE Jin   +5 more
doaj   +1 more source

LVRT Impact on Tower Loads, Drivetrain Torque and Rotational Speed—Measurement Results of a 2-MW Class DFIG Wind Turbine

open access: yesEnergies, 2021
With an increasing share in energy production, wind turbines have to fulfill strict grid requirements to support the grid in case of discontinuities. Here LVRT (Low Voltage Ride Through) compliance is one essential part, where the turbine has to stay ...
Mathias Arbeiter   +2 more
doaj   +1 more source

Research on Voltage Stability of Grid-Connected Photovoltaic System Based on Double-Side Voltage Feedback Control

open access: yesZhongguo dianli, 2022
In terms of the problem that the grid-connected photovoltaic DC system is unstable during low voltage ride through (LVRT), an improved double-side voltage control strategy is proposed.
Fei XUE   +3 more
doaj   +1 more source