Results 21 to 30 of about 74,432 (298)

Analysis of low voltage ride-through capability and optimal control strategy of doubly-fed wind farms under symmetrical fault

open access: yesProtection and Control of Modern Power Systems, 2023
Given the “carbon neutralization and carbon peak” policy, enhancing the low voltage ride-through (LVRT) capability of wind farms has become a current demand to ensure the safe and stable operation of power systems in the context of a possible severe ...
Botong Li   +5 more
semanticscholar   +1 more source

Low voltage ride-through of single-phase transformerless photovoltaic inverters [PDF]

open access: yes2013 IEEE Energy Conversion Congress and Exposition, 2013
Transformerless photovoltaic (PV) inverters are going to be more widely adopted in order to achieve high efficiency, as the penetration level of PV systems is continuously booming. However, problems may arise in highly PV-integrated distribution systems. For example, a sudden stoppage of all PV systems due to anti-islanding protection may contribute to
Yang, Yongheng; id_orcid 0000-0002-1488-4762   +2 more
openaire   +3 more sources

A Robust Low-Voltage-Ride-Through Strategy for Grid-Forming Converters Based on Reactive Power Synchronization

open access: yesIEEE transactions on power electronics, 2023
Grid-forming converters (GFMCs) prevail for their capability of providing voltage and frequency support in modern power grids with large integration of intermittent distributed power sources.
Han Deng   +4 more
semanticscholar   +1 more source

LVRT Impact on Tower Loads, Drivetrain Torque and Rotational Speed—Measurement Results of a 2-MW Class DFIG Wind Turbine

open access: yesEnergies, 2021
With an increasing share in energy production, wind turbines have to fulfill strict grid requirements to support the grid in case of discontinuities. Here LVRT (Low Voltage Ride Through) compliance is one essential part, where the turbine has to stay ...
Mathias Arbeiter   +2 more
doaj   +1 more source

Research on Voltage Stability of Grid-Connected Photovoltaic System Based on Double-Side Voltage Feedback Control

open access: yesZhongguo dianli, 2022
In terms of the problem that the grid-connected photovoltaic DC system is unstable during low voltage ride through (LVRT), an improved double-side voltage control strategy is proposed.
Fei XUE   +3 more
doaj   +1 more source

Probabilistic Short-Circuit Current in Active Distribution Networks Considering Low Voltage Ride-Through of Photovoltaic Generation

open access: yesIEEE Access, 2019
The probabilistic short-circuit current (PSCC) of photovoltaic generation is determined by the voltage sag at the grid connection and the low voltage ride-through of the unit during the grid fault, while the voltage sag and the low voltage ride-through ...
Weiyan Qian   +5 more
doaj   +1 more source

Application of UPFC to improve the low-voltage-ride-through capability of DFIG [PDF]

open access: yes2015 IEEE 24th International Symposium on Industrial Electronics (ISIE), 2015
In this paper, a new controller approach for unified power flow controller (UPFC) is proposed to improve the low-voltage-ride-through (LVRT) capability of a DFIG-based WECS during voltage sag. The shunt and series converters of the UPFC are controlled using a hysteresis current controller (HCC) and proportional integral controllers (PI), respectively ...
Yasser M. Alharbi, Ahmed Abu-Siada
openaire   +1 more source

On the Conflict between LVRT and Line Protection in LV Distribution Systems with PVs: A Current-Limitation-Based Solution

open access: yesEnergies, 2019
The upcoming adoption of low-voltage-ride-through requirements in low-voltage distribution systems is expected to raise significant challenges in the operation of grid-tied inverters.
Aristotelis Tsimtsios   +4 more
doaj   +1 more source

Design of a Microgrid with Low-Voltage Ride-Through Capability and Simulation Experiment [PDF]

open access: yesJournal of Applied Mathematics, 2014
A microgrid with low-voltage ride-through capability is designed. The designed microgrid avoids operating in unplanned islanded mode during an asymmetric ground fault which occurs in the low voltage distribution network and supports fault recovery for distribution network.
Fan, Wenchao   +5 more
openaire   +3 more sources

Research on low voltage ride through characteristics of distributed photovoltaic system

open access: yesEnergy Reports, 2023
The model of distributed PV is constructed firstly, then the characteristics of distributed PV are studied and the electromechanical transient current equations are given.
Yuhong Zhang   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy