Low Voltage Ride Through (LVRT) Capability Enhancement of Axial Flux Induction Generator-Based Wind Energy Conversion System

2020
With the remarkable increase in wind energy installed capacity, the wind energy conversion systems are also needed to be treated as conventional energy resources. These wind farms are required to be connected to grid as per grid codes during and as well as after the occurrence of short fault.
V. Ramesh Babu, A. Ganapathi
openaire   +1 more source

Reactive power capabilities of DFIG-based wind park for low-voltage ride-through (LVRT) performance

2013 International Conference on Quality, Reliability, Risk, Maintenance, and Safety Engineering (QR2MSE), 2013
This paper presents the principles and control schemes for the double-fed induction generator (DFIG)-based wind park. The wind turbine power tracking characteristics and the power flow mechanism of the DFIG-based wind plant are analyzed. The control strategies are presented, including the rotor-side converter (RSC) control, grid-side converter (GSC ...
openaire   +1 more source

Evaluation of Short Circuit Currents in Networks with Low Voltage Ride Through (LVRT) Enabled Voltage Source Converters (VSC) based Wind Turbines

2018 20th National Power Systems Conference (NPSC), 2018
Rapid depletion of the conventional energy sources has been a driving factor in the phenomenal advancements of renewable energy systems. Bulk integration of such renewable energy sources has given rise to a new dimension to various classical power system analysis problems impacting the system which need to be analysed before grid integration.
P.V.Praveen Gautam, Francis.C. Joseph
openaire   +1 more source

Computational analysis on Doubly fed induction generator to determine core loss under normal and low voltage ride through (LVRT) condition

2017 International Conference on Technological Advancements in Power and Energy ( TAP Energy), 2017
In present scenario, the Doubly Fed Induction Generator (DFIG) is contributing more than 50% in wind power generation. The computation of core losses and copper losses are essential to analyse the electric machine performance. In this paper, DFIG is modelled and analysed using ANSOFT MAXWELL which results in distribution of magnetic flux and magnetic ...
T Nikita, K. Manickavasagam, S Sachin
openaire   +1 more source

Onshore AC Grid Low Voltage Ride-Through (LVRT) of Diode-Rectifier Units based HVDC Transmission Systems for Offshore Wind Farms

2019 IEEE 10th International Symposium on Power Electronics for Distributed Generation Systems (PEDG), 2019
Diode-rectifier units based HVDC (DRU-HVDC) transmission systems, which consist of multiple distributed offshore DRUs and an onshore modular multilevel converter (MMC), are promising candidates for delivering offshore wind energy to shores in an efficient and cost-effective way.
Shenghui Cui   +2 more
openaire   +1 more source

Dynamic Voltage and Current Assignment Strategies of Nine-Switch-Converter-Based DFIG Wind Power System for Low-Voltage Ride-Through (LVRT) Under Symmetrical Grid Voltage Dip

IEEE Transactions on Industry Applications, 2016
This paper proposes the dynamic voltage and current assignment (DVCA) strategies for doubly fed induction generator (DFIG) wind power system, which is fed by nine-switch converter (NSC). With the proposed DVCA strategies, the voltage and current capacities of switches in NSC are dynamically assigned to the rotor- and grid-side branches, depending on ...
Gang Wen   +3 more
openaire   +1 more source

Nine-Switch-Converter-based DFIG Wind Power System and its dynamic port-current assigned approach for Low Voltage Riding Through (LVRT)

2015 IEEE Applied Power Electronics Conference and Exposition (APEC), 2015
This paper proposes a Doubly-Fed Induction Generator (DFIG) Wind Power System, which is driven by the novel Nine-Switch Converter (NSC). Considering the switches in the NSC are shared by two three-phase ports, a new adapted control method is proposed to flexibly control and fully use of the current capacity of the switches.
Gang Wen   +3 more
openaire   +1 more source

Low-voltage-ride-through (LVRT) capability of a phase-shifted-PWM STATCOM using the modular multilevel cascade converter based on single-star bridge-cells (MMCC-SSBC)

2013 IEEE Energy Conversion Congress and Exposition, 2013
This paper has an experimental discussion on low-voltage-ride-through (LVRT) capability of a phase-shifted-PWM STATCOM using the modular multilevel cascade converter based on single-star bridge-cells (MMCC-SSBC). The cluster-balancing control, that produces a significant effect on the LVRT capability, is modeled and analyzed with focus on either low ...
Joao Inacio Yutaka Ota   +2 more
openaire   +1 more source

A Comparative Analytical Study on Low-Voltage Ride-Through Reference-Current-Generation (LVRT-RCG) Strategies in Converter-Interfaced DER Units

2015
Recently, riding through grid faults and supporting the grid voltage under faults have become major requirements in distributed energy resource (DER) units. There have been also extensive efforts in academia and industry to develop and implement control strategies to ride through voltage disturbances, and even to support the grid under such faulted ...
openaire   +1 more source

An Overview of the Low Voltage Ride Through (LVRT) of Doubly-Fed Induction Generator

New Energy and Sustainable Development, 2016
Xue-Song Zhou, Zhen-Wei Qin, You-Jie Ma
openaire   +1 more source