Effects of cardiac motion on dose distribution during stereotactic arrhythmia radioablation treatment: A simulation and phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Cardiac motion may degrade dose distribution during stereotactic arrhythmia radioablation using the CyberKnife system, a robotic radiosurgery system. This study evaluated the dose distribution changes using a self‐made cardiac dynamic platform that mimics cardiac motion. Methods The cardiac dynamic platform was operated with amplitudes
Takayuki Miyachi   +6 more
wiley   +1 more source

Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós   +11 more
wiley   +1 more source

Automatic skin flash optimization in breast and chestwall VMAT with static angle modulated ports: Effect of HU and flash margin size on plan quality and robustness

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Skin flash is typically added to breast and chestwall plans to ensure robust target coverage in the presence of respiratory motion, anatomic changes, and small setup uncertainties. Adding skin flash in volumetric modulated arc therapy (VMAT) plans is an iterative and manual process.
Emily Hubley   +6 more
wiley   +1 more source

Erratum: Pretreatment Biopsy for Histological Diagnosis and Induction Therapy in Thymic Tumors

open access: yesChinese Journal of Lung Cancer, 2016
Editorial Office of Chinese Journal of Lung Cancer
doaj   +1 more source

Assessing HyperSight iterative CBCT for dose calculation in online adaptive radiotherapy for pelvis and breast patients compared to synthetic CT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose/objectives Recent technological advancements have increased efficiency for clinical deliverability of online‐adaptive‐radiotherapy (oART). Previous cone‐beam‐computed‐tomography (CBCT) generations lacked the ability to provide reliable Hounsfield‐units (HU), thus requiring oART workflows to rely on synthetic‐CT (sCT) images derived ...
Jingwei Duan   +7 more
wiley   +1 more source

Evaluating the use of diagnostic CT with flattening filter free beams for palliative radiotherapy: Dosimetric impact of scanner calibration variability

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut   +2 more
wiley   +1 more source

Improving organ dose sparing in left‐sided breast cancer with yaw‐limited volumetric modulated arc therapy: A dosimetric comparison to conventional and intensity modulated radiation therapy approaches

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background To assess the dose‐sparing capabilities of a yaw‐limited volumetric modulated arc therapy (YL_VMAT) beam setup for adjacent organs at risk (OAR) in comparison with 3D‐conventional radiation therapy (3D‐CRT), intensity‐modulated radiation therapy (IMRT) and conventional VMAT for radiation therapy in left‐sided breast cancer patients.
Gerhard Pollul   +4 more
wiley   +1 more source

Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka   +6 more
wiley   +1 more source