Results 161 to 170 of about 254,391 (317)

Assessing proton plans with three different beam delivery systems versus photon plans for head and neck tumors

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To compare plan quality among photon volumetric modulated arc therapy (VMAT) and intensity‐modulated proton therapy (IMPT) with robustness using three different proton beam delivery systems with various spot size (σ) ranges: cyclotron‐generated proton beams (CPBs) (σ: 2.7–7.0 mm), linear accelerator proton beams (LPBs) (σ: 2.9–5.5 mm),
Tara Gray   +9 more
wiley   +1 more source

Effect of obesity and site of surgery on perioperative lung volumes [PDF]

open access: bronze, 2004
Britta S. von Ungern‐Sternberg   +4 more
openalex   +1 more source

The effect of multi‐leaf collimator leaf width on VMAT treatment plan quality

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The advent of volumetric modulated arc therapy (VMAT) in radiotherapy has made it one of the most commonly used techniques in clinical practice. VMAT is the delivery of intensity modulated radiation therapy (IMRT) while the gantry is in motion, and existing literature has shown it has decreased treatment delivery times and the ...
Gregory Sadharanu Peiris   +3 more
wiley   +1 more source

Mediastinal Planning in Radiotherapy for Lung Cancer: Mediastinoscopy, Not PET Alone, Optimizes Volumes [PDF]

open access: bronze, 2005
Gregory M.M. Videtic   +6 more
openalex   +1 more source

The effect of kV imaging dose on PTV and OAR planning constraints in lung SBRT using stereoscopic/monoscopic real‐time tumor‐monitoring system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Quantify the impact of additional imaging doses on clinical dose constraints during lung stereotactic body radiotherapy (SBRT) treatment utilizing stereoscopic/monoscopic real‐time tumor monitoring. Materials and Methods Thirty lung SBRT patients treated with the volumetric arc therapy technique were randomly selected from the ...
Ruwan Abeywardhana, Mike Sattarivand
wiley   +1 more source

Motion corrected fetal body magnetic resonance imaging provides reliable 3D lung volumes in normal and abnormal fetuses. [PDF]

open access: yesPrenat Diagn, 2022
Davidson J   +9 more
europepmc   +1 more source

Lung and heart volumes by three-dimensional ultrasound in normal fetuses at 12–32 weeks' gestation [PDF]

open access: bronze, 2005
Cleisson Fábio Andrioli Peralta   +4 more
openalex   +1 more source

Effects of cardiac motion on dose distribution during stereotactic arrhythmia radioablation treatment: A simulation and phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Cardiac motion may degrade dose distribution during stereotactic arrhythmia radioablation using the CyberKnife system, a robotic radiosurgery system. This study evaluated the dose distribution changes using a self‐made cardiac dynamic platform that mimics cardiac motion. Methods The cardiac dynamic platform was operated with amplitudes
Takayuki Miyachi   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy