Low-voltage ride-through strategy for an integrated permanent magnet synchronous generator in a flexible interconnected distribution network

open access: yesFrontiers in Energy Research
For the permanent magnet synchronous generator (PMSG) integrated into the flexible interconnected distribution network (FIDN), its low-voltage ride-through (LVRT) strategy needs to be designed to enhance the transient operation capability of the FIDN ...
Lin Yang   +7 more
doaj   +1 more source

Mapping of grid faults and grid codes [PDF]

open access: yes, 2007
Contract no.
Anca Daniela Hansen   +4 more
core   +1 more source

Study on Low Voltage Ride Through for Direct-drive VSCF Wind Power System

open access: yesKongzhi Yu Xinxi Jishu, 2010
New grid regulation brings forward the requirements on wind turbines for having Low Voltage Ride Through(LVRT)capability and supplying reactive power compensation to the grid during voltage sag prcoess.
张宪平
doaj  

Research on the Control Strategy for Low Voltage Ride-through of Full Power Converter for Wind Turbine

open access: yesKongzhi Yu Xinxi Jishu, 2013
A control strategy of low voltage ride-through(LVRT) for full power converter is studied based on the system structure of 2.5 MW wind turbine with permanent magnet synchronous generator and the requirements of LVRT.
LUO Wenguang   +3 more
doaj  

Head-to-Head Comparison of Dual-Source and Split-Beam Filter Multi-Energy CT versus SPECT/CT for Assessing Lobar Lung Perfusion in Emphysema. [PDF]

open access: yesRadiol Cardiothorac Imaging, 2023
Strotzer QD   +10 more
europepmc   +1 more source

LVRT Research Based on Novel Energy Storage Control System [PDF]

open access: yesProceedings of the 3rd International Conference on Advances in Energy and Environmental Science 2015, 2015
Yangyang Miao   +4 more
openaire   +1 more source

Optimization Strategy of Wind Power Curtailment Under LVRT Operation

open access: yesIEEE Access
A novel wind power curtailment optimization method considering low-voltage ride through (LVRT) operation is developed. The reserve capacity of wind generation for reactive power output is necessary to ensure the proper operation of a wind power plant (WPP) when a voltage drop occurs.
openaire   +2 more sources

Low-Voltage Ride-Through Operation of Power Converters in Grid-Interactive Microgrids by Using Negative-Sequence Droop Control [PDF]

open access: yes, 2017
Guerrero, Josep M.   +5 more
core   +1 more source