Results 91 to 100 of about 5,131 (213)

LVRT Capacity Enhancement of DFIG Based Wind Farms by Controller Based Auxiliary Devices [PDF]

open access: yes, 2016
Wind energy is one of the most prominent sources of renewable energy. However, subjected to the high penetration of wind energy into existing power grids, stability and smooth operation of electric power system is at stake due to the vulnerability of the
Rashid, Gilmanur
core  

Value‐Based Reinforcement Learning for Inter‐Area Oscillations Mitigation in PV‐Integrated Power Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
Enhanced critic‐only DQN with smoothing enables continuous SVC control for damping inter‐area oscillations. The state selection via participation and residue analysis captures critical key modes. Orthogonal array efficiently tunes hyperparameters with low cost.
Gunawan Dewantoro   +3 more
wiley   +1 more source

Admittance‑Based Two‑Stage Optimisation of GFM‑STATCOM Parameters for Transient Voltage Support in DFIG Wind Farms

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper builds an admittance model for a DFIG‐STATCOM parallel system. Based on the system, the paper provides a method to optimise the control of the STATCOM, which aims to increase the performance of the system during symmetrical faults .
Wenhao Du   +5 more
wiley   +1 more source

Experimental LVRT performance of a 250 kW brushless DFIG

open access: yes, 2012
Nowadays, all new wind turbine generators have to meet strict grid codes, especially riding through certain grid faults, such as a low voltage caused by grid short circuits.
Malliband, P   +7 more
core  

Higher‐Order Statistics Based Pilot Protection Scheme for Wind Farm Transmission Line Connected to VSC Station

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper analyses the distribution of fault current samples for both external and internal faults conditions and quantifies the differences in the features by using the third‐order cumulant and kurtosis. On this basis, a pilot protection scheme was proposed for transmission lines wind farm transmission line connected to VSC station.
Ziliang Wu   +7 more
wiley   +1 more source

Addressing Distance Relay Mal‐Operation in Low‐Inertia Grids: A PLL‐Informed Power Swing Assessment

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A key advantage of the proposed approach is its independence from PLL control settings, relying solely on locally measured electrical quantities, which ensures robust, fast, and practical implementation in existing commercial distance relays. ABSTRACT The increasing penetration of inverter‐based resources (IBRs) has substantially reduced system inertia
Ahmad Reza Baghaei   +2 more
wiley   +1 more source

Mitigating Grid Stability Risks From Large AI Data Centres: A Three‐Mode Supervisory Control Framework for Centralized UPS Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A three‐mode supervisory control framework for centralized data centre UPS systems mitigates the grid stability risks posed by large AI facilities during transmission faults. The framework coordinates current‐limited reactive‐priority allocation, a minimum‐draw policy to limit aggregate load withdrawal and rate‐limited post‐fault recovery, extended to ...
Mohamed Shamseldein
wiley   +1 more source

Transient stability analysis and enhancement of renewable energy conversion system during LVRT [PDF]

open access: yes, 2019
Grid-connected renewable energy conversion systems (RECSs) are usually required by grid codes to possess the low voltage ride through (LVRT) and reactive power support capabilities so as to cope with grid voltage sags.
Hua, Geng, X, He, R, Li, Pal, BC
core   +1 more source

A Virtual Synchronous Generator Low-Voltage Ride-Through Control Strategy Considering Complex Grid Faults

open access: yesApplied Sciences
The Virtual Synchronous Generator (VSG) control strategy has garnered widespread application during the low-voltage ride-through (LVRT) of distributed energy resources integrated into power grids, primarily due to its inertia and damping properties ...
Jun Yin   +3 more
doaj   +1 more source

A study on the negative sequence current injection during LVRT of IBRs

open access: yesRE&PQJ
Low Voltage Ride Through (LVRT) behaviour of Inverter Based Resources (IBR) during asymmetrical grid faults is dictated by the requirements of Grid Code (GC) at the Point of Common Coupling (PCC) of the renewable energy plants. Earlier GCs demanded only positive sequence current injection, which gave freedom to inverter manufacturers to implement ...
A. Blázquez   +5 more
openaire   +1 more source