Results 101 to 110 of about 5,131 (213)
Low voltage ride-through capability improvement methods for DFIG based wind farm
In this paper the low voltage ride-through (LVRT) capability enhancement of the DFIG based wind farm (WF) is accomplished by using of the existing series devices like the new bridge type fault current limiter (NBFCL), new solid-state fault current ...
Md Emrad Hossain
doaj +1 more source
LVRT Reactive Current Index of Renewable Units Based on the Constraints of Transient Voltage
The renewable power gathering system often presents the characteristics of a weak AC grid. And the voltage fluctuates greatly during the failure process.
Kuo WANG, Hui LIU
core +1 more source
The increasing penetration of renewable energy has made the transient stability of new power systems a critical concern. Grid-forming (GFM) energy storage can provide voltage and frequency support for renewable energy stations.
Xiaolu Chen +7 more
doaj +1 more source
Enhanced wind turbine generator fault ride‐through capability by using hybrid on‐load tap changer
Low‐voltage ride‐through (LVRT) compliance of wind energy conversion systems is one of the significant concerns for both the wind industry and the system operator.
Hazem Karbouj, Zakir Hussain Rather
doaj +1 more source
A LVRT Technique Compensate Negative-sequence Reactive Power
Inverter-based distributed generation and related power quality problems have received much attention in recent years. Low-voltage ride-through (LVRT) is becoming mandatory in low-voltage system due to both security requirement and power-quality ...
Teng, Da-jyun
core
Simultaneous STATCOM and pitch angle control for improved LVRT capability of fixed-speed wind turbines [PDF]
A robust multivariable controller with the objective of enhancing the low-voltage ride-through (LVRT) capability of wind farms with fixed-speed induction generators is presented in this paper.
Valeri A. Ugrinovskii +13 more
core +1 more source
Challenges and Solutions for LVRT Problem in DFIG Machines based Wind Turbines
This paper discussed the challenges faced by the Wind energy systems based DFIG and LVRT problem existing techniques and compared the solutions from the stator side, rotor side and internal control techniques of DFIG.
MUNI PRAKASH (12453519)
core +1 more source
To effectively address the problem of low comprehensive simulation accuracy of dynamic equivalent models for offshore wind farms under diverse fault conditions, this paper proposes a dynamic equivalent modeling method for offshore wind farms based on cc (
Yankun Shi +6 more
doaj +1 more source
Enhancing the HVRT and LVRT Capabilities of DFIG-based Wind Turbine in an Islanded Microgrid
Doubly fed induction generator (DFIG) based wind turbines are very sensitive to grid voltage variations. Therefore, low-voltage-ride-through (LVRT) and high-voltage-ride-through (HVRT) capabilities are employed to improve DFIG performance during grid ...
Safaei, A. +2 more
core +1 more source
Impact of Grid Impedance on LVRT Performance of DFIG System With Rotor Crowbar Technology
Nowadays, most of the doubly fed induction generators (DFIGs) are equipped with rotor crowbar for the requirement of low voltage ride through (LVRT). The crowbar resistance is an important parameter, and it is selected taking rotor overcurrent and dc ...
Zakiud Din +4 more
doaj +1 more source