Results 71 to 80 of about 2,329,810 (183)

A new air gap flux‐based technique to detect loss of field in synchronous generators

open access: yesIET Electric Power Applications, Volume 18, Issue 5, Page 543-555, May 2024.
A new technique is proposed for loss of field (LOF) detection in synchronous generators (SGs). The proposed scheme employs the variations of SG angular velocity and load angle to reach this goal, while the mentioned parameters are estimated through air gap flux estimation.
Mohammad Reza Haseli   +2 more
wiley   +1 more source

Application of Variational Mode Decomposition and k-Nearest Neighbor Algorithm in the Quantitative Nondestructive Testing of Wire Ropes

open access: yesShock and Vibration, 2019
In this paper, we present a nondestructive testing device for wire rope by unsaturated magnetic excitation as an alternative to existing magnetic flux leakage (MFL) detection devices.
Pengbo Zheng, Juwei Zhang
doaj   +1 more source

Quantitative Inspection of Remanence of Broken Wire Rope Based on Compressed Sensing

open access: yesSensors, 2016
Most traditional strong magnetic inspection equipment has disadvantages such as big excitation devices, high weight, low detection precision, and inconvenient operation.
Juwei Zhang, Xiaojiang Tan
doaj   +1 more source

Analytical Modeling of Demagnetization Effects on Magnetic Flux Leakage Signals in Ferromagnetic Pipelines

open access: yesMagnetochemistry
Magnetic flux leakage (MFL) testing is a widely used non-destructive method for detecting defects in ferromagnetic pipelines. However, demagnetizing fields in ferromagnetic materials can distort MFL signals, reducing detection accuracy.
Jiawen Zhang   +5 more
doaj   +1 more source

Non-Destructive Evaluation Technique for Continuum Structures Using Non-Contact Magnetic Flux Leakage(MFL) Measurement

open access: yesJournal of the Korean Society for Nondestructive Testing, 2016
이러한 연속체 구조물의 경우 대부분 외부환경에 노출되어 있어 다양한 환경적, 물리적 요인으로 인해 부식, 크랙, 단선과 같은 국부손상이 발생하게 될 수 있는데 이러한 손상에 대한 초기 대처가 늦을 경우 특정부의 응력 집중, 유체누출 등과 같은 원인으로 구조물 전체의 대형 사고로 이어질 수 있는 위험성을 가지고 있다.따라서 이러한 위험성을 조기에 방지하기 위해 부재에 발생한 손상을 초기에 발견할 수 있는 검사법이 필수적인데, 짧게는 수십 미터에서 길게는 수천 킬로미터까지 이어지는 거대한 연속체 구조물의 특성상, 적용되는 검사법은 신뢰성과 더불어 경제성을 반드시 요구하게 된다.
openaire   +2 more sources

Research on Pipeline Magnetic Flux Leakage Testing Defect Classification Based on Generate Expansion and Dual-Channel Vision Transformer

open access: yesApplied Sciences
Magnetic flux leakage (MFL) testing is a vital non-destructive testing method used to identify defects in oil and gas pipelines and critical components.
Xulai Zhu   +6 more
doaj   +1 more source

88th Annual Meeting of the Meteoritical Society 2026: Abstracts

open access: yes
Meteoritics &Planetary Science, Volume 61, Issue S1, Page S48-S551, August 2026.
wiley   +1 more source

Modeling and Interpretation Magnetic Flux Leakage

open access: yes, 2012
This work presents an analysis of Magnetic Flux Leakage (MFL) signal to better understand the forward problem and the physics contributing to the nature of the signals.
Trevino Garcia, David A.
core  

Numerical simulation on magnetic flux leakage testing at high speed

open access: yes
High-speed non-destructive inspection (NDI) systems using magnetic flux leakage method (MFL) is in great demand in online metal inspection and defect characterisation, especially in pipeline and rail track inspection.
Tian GY, Li Y, Ward S
core   +5 more sources

Design and Optimization of an MFL Coil Sensor Apparatus Based on Numerical Survey

open access: yesSensors, 2019
In this study, we aimed to design a coil sensor prototype capable of detecting metallic area loss based on numerical simulations using the magnetic flux leakage (MFL) method. Unlike previous numerical simulation-based studies, which are only conducted to
Ali Azad, Namgyu Kim
doaj   +1 more source