Results 101 to 110 of about 2,501,390 (313)

Single‐Incision Anterolateral Thoracotomy for LVAD Implantation: A Novel Minimally Invasive Approach

open access: yesArtificial Organs, EarlyView.
A novel single‐incision anterolateral thoracotomy technique enables complete HeartMate 3 implantation without sternotomy, minimizing surgical trauma and accelerating recovery. This minimally invasive approach is feasible, safe, and may represent a new standard in advanced heart failure surgery.
Ali Saad Merzah   +9 more
wiley   +1 more source

The Impact of Obesity on Durable Left Ventricular Assist Device Implantation: A Systematic Review and Meta‐Analysis

open access: yesArtificial Organs, EarlyView.
14 100 LVAD patients across 21 studies were analyzed. Findings indicated that obese LVAD recipients had lower short‐term mortality and higher risk of infection, thrombosis and right heart failure. There was no difference in long‐term survival between obese and non‐obese patients.
Hugh Jacobs   +11 more
wiley   +1 more source

Influence of Brownian Diffusion on Levitation of Bodies in Magnetic Fluid [PDF]

open access: yesЖурнал нано- та електронної фізики, 2013
The present work deals with experimental investigation of the levitation of magnetic and non-magnetic bodies in a magnetic fluid when essentially influenced by Brownian diffusion of magnetic particles in it. It is established that the point of levitation
V. Bashtovoi   +6 more
doaj  

Driveline Infections Among Patients Supported With Left Ventricular Assist Devices: A Single Center Sixteen‐Year Longitudinal Profile

open access: yesArtificial Organs, EarlyView.
Our study of 1026 LVAD implants revealed HeartWare had lower driveline infection rates than other LVAD types. In addition, severe diabetes was associated with higher risk, while older age and coronary artery disease were linked to a lower risk of driveline infections.
Anh Nguyen   +6 more
wiley   +1 more source

Variable Structure Control Design for a Magnetic Levitation System

open access: yesJournal of Engineering, 2018
In this paper the variable structure control theory is utilized to derive a discontinuous controller to the magnetic levitation system. The magnetic levitation system model is considered uncertain, which subjected to the uncertainty in system parameters,
Shibly Ahmed Al-Samarraie
doaj   +1 more source

A study on the design of propulsion/levitation/guidance integrated DSLIM with non-symmetric structure

open access: yesAIP Advances, 2020
Research on the magnetic levitation driving system of Hyperloop which has emerged as the next new vehicle is being carried out. Recently, magnetic levitation driving systems use EMS (Electro-Magnetic Suspension) and EDS (Electro-Dynamic Suspension ...
Kyo-Young Seo   +5 more
doaj   +1 more source

Hemocompatibility and Long‐Term Outcomes in HeartWare Versus HeartMate II Versus HeartMate 3: Multicenter Real‐World Cohort

open access: yesArtificial Organs, EarlyView.
Multicenter real‐world cohort (n = 327) comparing LVADs: HeartMate 3 (HM3), HeartMate II (HMII), and HeartWare (HVAD). HM3 showed superior long‐term survival versus legacy devices, driven by fewer hemocompatibility‐related adverse events, especially pump thrombosis and ischemic stroke, while major bleeding was similar across devices.
Hamza H. H. Ben Nasir   +9 more
wiley   +1 more source

Magnetic Forces Investigation of Bulk HTS over Permanent Magnetic Guideway under Different Lateral Offset with 3D-Model Numerical Method

open access: yesAdvances in Materials Science and Engineering, 2012
Magnetic forces of a cylinder shape bulk high-temperature superconductor (HTS) over a permanent magnet guideway (PMG) are studied mathematically. One cylindrical bulk HTS with a diameter of 30 mm and 15 mm in height is used. Two types of PMG are employed
Yiyun Lu, Qiaohong Dang
doaj   +1 more source

Consideration on bent magnetic levitation apparatus for thin steel plate

open access: yesNihon Kikai Gakkai ronbunshu, 2015
In the transport system of a thin steel plate production line, there is a problem that the quality of the plate surface deteriorates over time because the plate is usually in contact with rollers.
Hiroki MARUMORI   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy