Results 81 to 90 of about 4,760 (231)
Analog Magnetic Levitation System [PDF]
Indiana University Purdue University IndianapolisThe Magnetic Levitation System operates as a closed-loop system, incorporating a photoresistor to provide feedback.
Martinez, Ricardo +2 more
core +2 more sources
Feedback control system : magnetic levitation [PDF]
Access is limited to UniMAP community.This report, entitled “Feedback Control System: Magnetic Levitation System” summarizes the entire final year project for the Electrical System engineering courses done in Universiti Malaysia Perlis (UniMAP).
Mohamad Nawal Sahrani
core
ABSTRACT In this study, a robust position control strategy is presented for a two‐stage electro‐hydraulic actuator system using a fractional‐order proportional–integral–derivative (FOPID) controller tuned by Kirchhoff's law algorithm (KLA). Electro‐hydraulic systems exhibit strong nonlinearities, parameter uncertainties, and external disturbances ...
Ridvan Firat Cinar +8 more
wiley +1 more source
Real‐Time Fractional Control of an Electrohydraulic System Using Low‐Cost Technology
ABSTRACT Advances in control methods for electrohydraulic systems (EHS) improve performance by addressing nonlinearities and unknown parameters, although most studies are limited to numerical simulations. Furthermore, research with experimental validation often relies on high‐performance computing equipment, specialized data acquisition cards, and ...
Edgar H. Robles‐Sauceda +5 more
wiley +1 more source
Magnetic suspension balance systems (MSBSs) need to allow vehicle models to levitate stably in different attitudes, so it is difficult to ensure the stable performance of the system under different levitation gaps using a controller designed with single ...
Ziyu Liu, Fengshan Dou
doaj +1 more source
Small‐Scale Magnetic Soft Robots for Medical Applications: From Laboratory to Clinical Use
Small‐scale magnetic soft robots are emerging as promising platforms for minimally invasive diagnosis and therapy in complex in vivo environments. This review compares untethered and tethered medical magnetic robots in parallel across five translational stages, from basic performance testing to clinical evaluation.
Xingxing Ke +29 more
wiley +1 more source
MAGNETIC LEVITATION TRANSPORTATION SYSTEM [PDF]
This paper involves the design and hardware implementation of control system required for “Magnetic levitation of transportation system.”The maglev transportation system is more stable for levitation of vehicle by utilizing lead compensator.It is found ...
Mane, Prachita, Mane, Trupti
core +1 more source
Shear‐induced blood damage—including hemolysis, platelet and neutrophil injury, and von Willebrand factor (vWF) degradation—was evaluated for the BrioVAD and HM3 using an in vitro circulatory loop under clinically relevant conditions. Across 15 biomarkers (n > 6 per group), no significant differences were observed between the two devices.
Wenji Sun +9 more
wiley +1 more source
Robust Feedback Control Analysis of Magnetic Levitation System [PDF]
The Magnetic Levitation System is one of the important benchmark laboratory models for the design and analysis of feedback control systems. Robust feedback control for magnetic levitation systems is considered problematic due to the parametric ...
Choudhary, S.K.
core +1 more source
Blade shapes (leading‐edge geometry and thickness) in rotodynamic blood pumps were systematically evaluated. Thinner blades improve pump efficiency by reducing blockage effects, while neither blade thickness nor leading‐edge geometry shows clear hemocompatibility benefits. Overall, blade shape has a limited impact on hemocompatibility, indicating it is
Benjamin Torner +7 more
wiley +1 more source