Results 61 to 70 of about 20,745 (206)
Sonographic imaging is used to identify the presence, number and location of malignant lymph nodes. Axillary lymph nodes suspicious of harbouring breast cancer metastasis can be localised to three surgical axillary levels. This paper will unpack the axillary anatomy, muscular sonographic landmarks, surgical axillary lymph node levels and the ...
Michelle Fenech +4 more
wiley +1 more source
Accuracy of Key Sonographic Markers for Juxta‐Articular Fractures
Objectives To systematically evaluate sonographic features of long bone juxta‐articular fractures and identify key diagnostic predictors using machine learning‐based feature selection. Methods This prospective single‐center diagnostic accuracy study enrolled 121 patients with clinically suspected juxta‐articular fractures.
Xiaofang Fu +11 more
wiley +1 more source
: Background: Cardiac cine imaging is routinely used in patient with suspected or known cardiac dysfunction. Water and fat (W/F) separated cardiovascular magnetic resonance (CMR) will be helpful to distinguish adipose tissue, blood, and myocardium ...
Tzu Cheng Chao +3 more
doaj +1 more source
Deep Learning‐Based Dynamic Segmentation of the Left Atrium in 4D Flow MRI
ABSTRACT Purpose To design a deep learning pipeline for automated, time‐resolved segmentation of the left atrium (LA) from 4D flow MRI data. Methods We studied 100 individuals including 65 patients with atrial fibrillation (AF) and 35 healthy subjects (HS) resulting in 2530 4D flow MRI time‐volumes acquired in different centers and scanners.
Jonas Leite +16 more
wiley +1 more source
Evaluation of Cardiac Motion and Function by Cine Magnetic Resonance Imaging.
Cardiac cine magnetic resonance imaging (MRI) was studied to evaluated the cardiac motion and function, and a water-stream phantom study was performed to clarify whether it was possible to quantitatively assess the valvular regurgitation flow by the size of the flow void.
KONDO, TAKESHI +10 more
openaire +3 more sources
Fast Localized Calibration for Spatial‐Spectral Excitation Without Fly‐Back Gradients
ABSTRACT Purpose Standard spatial‐spectral excitation pulses apply a fly‐back gradient between sub‐pulses, limiting, for example, how thin the slices can be (> 4 mm). Without fly‐back gradients, slices can be as thin as 1.7 mm but require a phase calibration for the sub‐pulses with inverted gradients due to system imperfections.
Michael Schär +3 more
wiley +1 more source
Background: Malignant neoplasms originating from or involving the mediastinum represent a diagnostic and therapeutic challenge when they are in contact with nearby cardiovascular structures.
Umberto Cariboni +6 more
doaj +1 more source
ABSTRACT Purpose To develop a unified image reconstruction framework that bridges real‐time and gated cardiac MRI, including quantitative MRI. Methods We introduce generative multitasking, which learns subject‐ and dataset‐specific implicit neural temporal bases from sequence timings and an interpretable latent space for cardiac and respiratory motion.
Xinguo Fang, Anthony G. Christodoulou
wiley +1 more source
3T MRI evaluation of regional catecholamine-producing tumor-induced myocardial injury
Objective: Regional differences in cardiac magnetic resonance, which can reveal catecholamine-induced myocardial injury in patients with pheochromocytoma, have not yet been assessed using 3T magnetic resonance imaging.
Satoshi Higuchi +9 more
doaj +1 more source
ABSTRACT Purpose To validate the performance of an open‐source cardiac diffusion sequence framework and to investigate hardware‐based performance differences. Methods Three second order motion compensated sequence files were compiled using Pulseq and applied across different MRI systems to image five volunteers.
Eric Arbes +7 more
wiley +1 more source

