Results 21 to 30 of about 87,411 (258)

Solution-Based Ultraviolet Photodiode with ZnO Nanoparticle/Poly(3,4-Ethylenedioxythiophene) Polystyrene Sulfonate Heterojunction and Negative Capacitance

open access: yesAdvanced Devices & Instrumentation
Ultraviolet (UV) detectors have been widely applied to extensive fields, such as photoelectric microsensors, UV imaging, optical communications, and biological detection.
Jin Li   +4 more
doaj   +1 more source

Sensitivity Enhancement in Magnetic Sensors Based on Ferroelectric-Bimorphs and Multiferroic Composites

open access: yesSensors, 2016
Multiferroic composites with ferromagnetic and ferroelectric phases have been studied in recent years for use as sensors of AC and DC magnetic fields. Their operation is based on magneto-electric (ME) coupling between the electric and magnetic subsystems
Gollapudi Sreenivasulu   +4 more
doaj   +1 more source

Development of an Embedded Myokinetic Prosthetic Hand Controller

open access: yesSensors, 2019
The quest for an intuitive and physiologically appropriate human machine interface for the control of dexterous prostheses is far from being completed. In the last decade, much effort has been dedicated to explore innovative control strategies based on ...
Francesco Clemente   +3 more
doaj   +1 more source

European Standard Clinical Practice Guideline and EXPeRT Recommendations for the Diagnosis and Management of Gastroenteropancreatic Neuroendocrine Neoplasms in Children and Adolescents

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Pediatric gastroenteropancreatic neuroendocrine neoplasms (GEP‐NENs) are extremely rare and clinically heterogeneous. Management has largely been extrapolated from adult practice. This European Standard Clinical Practice Guideline (ESCP), developed by the EXPeRT network in collaboration with adult NEN experts, provides (adult) evidence ...
Michaela Kuhlen   +23 more
wiley   +1 more source

Dealing with Magnetic Disturbances in Human Motion Capture: A Survey of Techniques

open access: yesMicromachines, 2016
Magnetic-Inertial Measurement Units (MIMUs) based on microelectromechanical (MEMS) technologies are widespread in contexts such as human motion tracking.
Gabriele Ligorio, Angelo Maria Sabatini
doaj   +1 more source

A Model for the Magnetoimpedance Effect in Non-Symmetric Nanostructured Multilayered Films with Ferrogel Coverings

open access: yesSensors, 2021
Magnetoimpedance (MI) biosensors for the detection of in-tissue incorporated magnetic nanoparticles are a subject of special interest. The possibility of the detection of the ferrogel samples mimicking the natural tissues with nanoparticles was proven ...
Nikita A. Buznikov   +1 more
doaj   +1 more source

Guidelines for Pediatric Radiotherapy Simulation: A Report From the Children's Oncology Group Radiation Oncology Discipline

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Pediatric radiation therapy presents unique challenges compared to adult treatments, including those of immobilization, potential need for sedation, and the critical importance of accurate, reproducible positioning. Additionally, heightened attention to imaging doses is necessary to minimize long‐term toxicity in survivors.
Parham Alaei   +17 more
wiley   +1 more source

Research progress and development trends of fiber optic magnetic field sensors

open access: yes地震科学进展
Magnetic field sensors have extensive applications in various fields such as resource exploration, industrial production, and geomagnetic detection. Traditional electric magnetic field sensors have good stability, but they have disadvantages such as ...
Yuntian Teng   +4 more
doaj   +1 more source

A Magnetic Sensor with Amorphous Wire [PDF]

open access: yesSensors, 2014
Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz.
Dongfeng He, Mitsuharu Shiwa
openaire   +3 more sources

T2* Magnetic Resonance Imaging Uncovers Hemosiderin Burden in Pediatric Hemophilia: A Call for Sensitive Imaging Biomarkers

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Hemophilic arthropathy remains the leading morbidity in hemophilia despite modern prophylaxis, and early joint damage may be missed by routine exams. This study explored T2* MRI as a noninvasive biomarker of hemosiderin deposition in pediatric hemophilia.
Jessica Garcia   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy