Results 121 to 130 of about 28,138 (266)
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
ABSTRACT The thermal state of underground power cables can be monitored based on the temperature dependency of the dielectric permittivity of the insulation material. The resulting temperature‐dependent wave velocity is used as a thermometric property. To this end, the signal propagation time along a cable of an injected signal is determined.
Peter Wouters +2 more
wiley +1 more source
Adult Patient With Spontaneous Intrahepatic Portosystemic Venous Shunt: MRI Findings
Spontaneous intrahepatic portosystemic venous shunt is a rare pathology that can be either congeni-tal or acquired, and may cause hepatic encephalopathy.
İlhan Erden +2 more
core
The Graphical Abstract depicts the proposed Artificial Bee Colony algorithm‐based optimal tuning of PI controllers for back‐to‐back Voltage Source Converters in a hybrid wind–PV system. ABSTRACT This paper proposes a hybrid model‐based back‐to‐back voltage‐source converter (B2B‐VSC) system comprising a Photovoltaic (PV) array and a Permanent Magnet ...
Ch. Sreenu +3 more
wiley +1 more source
Optimizing of transformer with developed transverse magnetic leakage fluxes and magnetic shunt
Предложена оптимизационная модель однофазного трансформатора с развитыми поперечными магнитными потоками рассеяния и подвижным магнитным шунтом для обеспечения плавного регулирования сварочного тока.
Рымар, С.В.
core
Embolic Agent Selection and Outcomes in Renal Angiomyolipoma Embolisation
ABSTRACT Purpose To evaluate whether embolic agent selection influences outcomes following selective arterial embolisation (SAE) of renal angiomyolipomas (r‐AMLs) and to assess procedural safety and effects on renal function. Materials and Methods A retrospective observational study was performed of all r‐AML SAEs undertaken at a tertiary institution ...
Ross O'Shea +7 more
wiley +1 more source
Vibration Suppression of Beam by Using Electromagnetic Shunt Damper
In this paper the electromagnetic shunt damper was newly employed for vibration suppression of the flexible structures. The electromagnetic shunt damper consists of a coil and a permanent magnet.
오일권, 임승현, 성태홍
core
In a mixed diagnostic cohort of pathologically diagnosed Alzheimer's disease, cerebrovascular disease, mixed pathology, and control tissue, we connected the histopathological wasteosome profile in periventricular (PV) brain sections to 7T FLAIR‐MRI confirmed PV white matter hyperintensities (WMHs), vascular stenosis and perivascular space size ...
Nikita Ollen‐Bittle +7 more
wiley +1 more source
Chronic overcirculation-induced pulmonary arterial hypertension in aorto-caval shunt.
Pulmonary arterial hypertension is a common complication of congenital heart defects with left-to-right shunts. Current preclinical models do not reproduce clinical characteristics of shunt-related pulmonary hypertension.
MERIGO, Flavia +9 more
core +1 more source
ABSTRACT Key Content Neurovascular conditions in pregnancy are rare but are associated with poor maternal and fetal outcomes. This review covers the prevalence, clinical presentation, diagnosis and management of neurovascular disorders in pregnancy. The approach to clinical assessment and investigation of pregnant women with acute or changing chronic ...
Amy Newnham +5 more
wiley +1 more source

