Seismic Performance of Multistorey Masonry Structure with Openings Repaired with CFRP Grid [PDF]
FRP composites have been used for strengthening RC and masonry structures for decades. However, the researches on repairing multistorey masonry structures using FRP grids were relative less.
Jin-Ben Gu +4 more
doaj +3 more sources
Numerical simulation of autoclaved aerated concrete masonry wall subjected to close-in explosion and the structural damage assessment [PDF]
In this study, we investigated the destructive effect of autoclaved aerated concrete (AAC) masonry walls subjected to close-in explosions. First, full-size refined finite-element models of the AAC masonry wall were established, and the accuracy of the ...
Sheng Liu +4 more
doaj +2 more sources
Dynamic Response of Masonry Structures to Temperature Variations: Experimental Investigation of a Brick Masonry Wall [PDF]
Structural health monitoring (SHM) is essential for preserving historical and modern infrastructure by tracking dynamic properties such as frequencies and mode shapes.
Daniele Pellegrini +3 more
doaj +2 more sources
In-Plane Cyclic Response of Separated Masonry Infill Walls Using Polymeric Materials at the Surrounding Steel Frames Interface Using 3D FE Analysis [PDF]
Masonry infill walls are commonly used as partitions and exterior walls in many countries. Generally, the masonry wall is executed without any gap from the frame, which leads to the interaction between the structural frame and the infill wall ...
Alireza Karkabadi +1 more
doaj +1 more source
Numerical Study on Seismic Behavior of Moment-Resistant Steel Frames with Hybrid Masonry Infill [PDF]
Hybrid masonry system is a new structural system, in which the masonry panels link to the frame with steel plate connections. Hybrid masonry uses masonry infill for lateral stiffness and strength within frames in addition to supporting out-of-plane ...
Mahmoud Reza ُُShiravand +1 more
doaj +1 more source
Tube-Jack Testing for Irregular Masonry Walls: Regular Masonry Wall Testing [PDF]
This paper presents the continued development of a novel non-destructive testing method termed tube-jack testing. The goal of the tube-jack system is to provide an enhanced and less destructive method than traditional flat-jack testing for determination of mechanical characteristics and local stress states in irregular masonry walls.
Elizabeth Manning +2 more
openaire +2 more sources
Unreinforced masonry has been used as a construction material for thousands of years. Whilesome of these structures survive to this day, these tend to have massive walls and would be unpractical formodern use. Unreinforced masonry can be reinforced with proper masonry techniques.
M. Djeffal, A. Merdas
openaire +1 more source
Labor Productivity Improvement Obtained by Masonry Walls Project Design Implementation [PDF]
This paper aims to quantify the labor productivity improvement reached by the implementation of a masonry wall project design to guide field construction.
Francielle Santos +5 more
doaj +1 more source
A Model for In-Plane Capacity of Multi-Leaf Stone Masonry Walls
Masonry walls with distinct layers, known as multi-leaf masonry walls, are prevalent in many regions of the world including ancient architecture in Europe and new construction in the Himalayan region of South Asia.
Jagat Kumar Shrestha, Sujit Bhandari
doaj +1 more source
The steel frame infilled with the autoclaved lightweight aerated concrete (AAC) masonry wall is widely applied in buildings. However, earthquake damage investigation has revealed that infill walls have a significant influence on the mechanical behaviors ...
You-Sheng Yu +3 more
doaj +1 more source

