Results 71 to 80 of about 10,040 (154)

X‐ray and γ‐ray Sensing from Aqueous‐Based Lead Sulfide Telluride Nanocomposites

open access: yesSmall, Volume 21, Issue 49, December 10, 2025.
PbSxTey nanoparticles integrate into flexible, size‐scalable aramid polymeric scaffolds, forming percolation paths capable of efficiently transporting the electrons and holes created by penetrating photonic interactions. The resulting nanosemiconductor‐nanofiber composite forms the basis for room‐temperature spectroscopic sensors of X‐rays and γ‐rays ...
Vinh‐Dien Le   +6 more
wiley   +1 more source

Validation and Application of MCNP and TORT Source Generation Codes

open access: yesEnergy Procedia, 2017
Abstract Primary Shielding Calculation (PSC) plays an important role in reactor shielding design and analysis. In order to facilitate PSC, a source generation code is developed to generate cumulative distribution functions (CDF) for the source particle sample code of the MCNP code, and a source particle sample code is developed to sample source ...
Zheng Zheng, Qiliang Mei, Hui Li
openaire   +1 more source

Gamma-ray fluxes in Oklo natural reactors

open access: yes, 2012
Uncertainty in the operating temperatures of Oklo reactor zones impacts the precision of bounds derived for time variation of the fine structure constant $\alpha$.
Gould, C. R.   +2 more
core   +1 more source

Correlation Patterns of Muon Flux With Vertical Atmospheric Profiles: Insights From Monte Carlo Simulations

open access: yesJournal of Geophysical Research: Space Physics, Volume 130, Issue 11, November 2025.
Abstract The production, attenuation, and absorption of secondary cosmic rays (SCR) are influenced by atmospheric parameters such as air pressure and temperature. To reliably correlate SCR flux measurements with atmospheric ionization driven by energetic particle precipitation, these dependencies must be quantified.
A. Al‐Qaaod   +11 more
wiley   +1 more source

A Monte-Carlo Benchmark of TRIPOLI-4® and MCNP on ITER neutronics

open access: yesEPJ Web of Conferences, 2017
Radiation protection and shielding studies are often based on the extensive use of 3D Monte-Carlo neutron and photon transport simulations. ITER organization hence recommends the use of MCNP-5 code (version 1.60), in association with the FENDL-2.1 ...
Blanchet David   +15 more
doaj   +1 more source

Determination of the 52Cr resonance parameters from a set of the neutron transmissions obtained by average energy shift method for filtered neutrons [PDF]

open access: yesЯдерна фізика та енергетика, 2018
The parameters ER, Гn and R/ for 52Cr resonance at the energy of 50 keV were determined from the set of the experimental average transmissions obtained by the shifting of average energy of the filtered neutrons.
О. О. Gritzay   +2 more
doaj   +1 more source

131I-Chlorotoxin dosimetry in liver using MCNP simulation code

open access: yesArchives of Advances in Biosciences, 2013
     Chlorotoxin is a 36 amino acids peptide, which is able to block chloride channels isolated from mouse brain. A derivative of chlorotoxin is synthesized and it is labeled by iodine 131; then animal experiments carry out on rats. Multiple organ doses may be calculated with biological distribution results in rats with labeled compounds using ...
Amiri, Jamal   +6 more
openaire   +1 more source

Iterative Determination of Distributions by the Monte Carlo Method in Problems with an External Source

open access: yes, 2013
In the Monte Carlo (MC) method statistical noise is usually present. Statistical noise may become dominant in the calculation of a distribution, usually by iteration, but is less Important in calculating integrals.
Makai, Mihály, Szatmáry, Zoltán
core   +1 more source

A comparative study of clinically used fast Monte Carlo dose engines for proton therapy

open access: yesJournal of Applied Clinical Medical Physics, Volume 26, Issue 10, October 2025.
Abstract Background Several fast Monte Carlo (MC) codes have been implemented and used to simulate proton transport and calculate patient doses in proton therapy. The resulting dose is typically compared to full MC codes, rather than other fast MC codes.
Sherif M. Gadoue, Narayan Sahoo
wiley   +1 more source

Estimation of nuclear heating by delayed gamma rays from radioactive structural materials of HANARO

open access: yesNuclear Engineering and Technology, 2018
To improve the accuracy and safety of irradiation tests in High flux Advanced Neutron Application ReactOr (HANARO), the nuclear energy deposition rate, which is called nuclear heating, was estimated for an irradiation capsule with an iridium sample in ...
Tae-yang Noh   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy