Results 101 to 110 of about 4,301,510 (286)
This paper reports and analyzes the failure modes of a 1.2 kV low voltage (LV) solid-state dc circuit breaker (DCCB) over 3,000,000+ opening operations.
Yang Liu +4 more
doaj +1 more source
Conventional contact‐separation triboelectric nanogenerators generate high voltage but deliver limited power due to premature charge dissipation. Here, a capacitive charge reservoir architecture decouples charge accumulation from discharge triggering, enabling sequential voltage amplification via floating‐layer capacitive coupling.
Ajay Haridas CP +3 more
wiley +1 more source
Solid-state circuit breakers (SSCBs) provide fast, arcless fault clearance, resulting in a longer service life compared to mechanical circuit breakers (MCBs) in DC grids.
Hans Vincent Lianto +3 more
doaj +1 more source
This work demonstrates the implementation of MOF‐assisted anode and cathode materials for prolonged cycling of zinc‐air batteries with strong redox capability and structural stability. ABSTRACT The surface modification of zinc anodes and the development of effective cathode dual‐functional oxygen electrocatalysts remain of paramount interest for ...
Ramasamy Santhosh Kumar +7 more
wiley +1 more source
Research of simulation and experiment on arc characteristics of gas mechanical switch
An arc is the high‐temperature discharge plasma produced in the opening process of mechanical switches, which directly affects the breaking capability of a hybrid DC circuit breaker.
Cheng Jiang +7 more
doaj +1 more source
Energy‐harvesting‐integrated sensors couple ambient energy conversion with sensing, processing, and wireless communication. This review organizes recent progress through integration architectures and operating principles, revisiting co‐packaged, monolithic, and co‐functional designs together with always‐on, event‐driven, and multi‐modal sensing modes ...
Taehyun Park +5 more
wiley +1 more source
Fast and selective faulted-section identification is challenging in multiterminal medium-voltage DC (MVDC) ring networks because the initial fault transient is affected by converter dynamics, fault resistance, line parameters, and multiple feeding paths.
Chi Zhang +7 more
doaj +1 more source
Arthropod‐Inspired Miniature Modular Vibration Direct‐Drive Robot With Untethered Locomotion
This work presents an arthropod‐inspired untethered miniature modular vibration direct‐drive robot. By utilizing standardized driving units and nested locking interfaces, on‐demand reconfiguration into quadruped, hexapod, octopod, and circular morphologies is achieved.
Shijing Zhang +4 more
wiley +1 more source
DC/DC VOLTAGE CONVERTER PROVIDED WITH A CIRCUIT-BREAKER DEVICE
Disclosed is a voltage converter (10) comprising at least one arm (24) extending between a first DC terminal (16) and a second DC terminal (28) and comprising at least one upper half-arm (24u) and one lower half-arm (24l) that are connected, each half ...
Dworakowski, Piotr +5 more
core +1 more source
An adaptive reclosing strategy for high-voltage DC grids with mechanical DC circuit breakers
Yanxun Guo, Zhuang Xu, Xiaomei Yao
openaire +1 more source