Results 31 to 40 of about 4,301,510 (286)
Faults in DC systems are difficult to interrupt compared to their AC counterparts due to absence of natural current-zero (CZ) crossing in DC current. This puts forward the need of enhanced arc chambers inside the circuit-breaker to cope with DC arc.
Virdag, Muhammad-Ali-Khan
core +1 more source
Recently, there has been significant interest in developing the modular multilevel converter (MMC) based DC grids in the power industry. However, the immature DC circuit breaker (DCCB) technology hampers the development of DC grids in overhead lines ...
Binye Ni +4 more
doaj +1 more source
Interlink Hybrid DC Circuit Breaker [PDF]
—To protect HVDC grids from DC faults, the concept of a hybrid DC circuit breaker is widely accepted due to its low conduction losses and fast interruption speed.
Chuanyue Li +5 more
core +1 more source
Although traditional electromechanical circuit breakers have a proven track record as efficient and reliable circuit safety devices. Emerging power distribution technologies and architectures such as DC microgrids require advanced breaking performance ...
Muhammad Zulqair Nain, Tahir Mahmood
doaj +1 more source
Application of Surge Arrester in Limiting Voltage Stress at DC Breaker
Three categories of DC breakers; namely, static, mechanical, and hybrid dc breakers are currently available. DC circuit breakers have been considered for DC system protection with the development of DC generations, loads and circuits.
Mehraeen, Shahab +2 more
core +1 more source
Modeling and Simulation of ±10 kV DC Transmission System based on Mechanical DC Circuit Breaker
Abstract In order to simulate the interruption process of mechanical DC circuit breaker in actual DC power grid and obtain various stress characteristics of DC circuit breaker in actual interruption process, it is necessary to establish a stable and effective flexible DC system model with good dynamic performance.
Jiashuo Cui +3 more
openaire +1 more source
Mechanism and suppression of breaking overvoltage of DC circuit breakers
Abstract The occurrence of breaking overvoltage in a DC circuit breaker (DCCB) poses a potential threat to the safe operation of a DC grid. Based on the structure of the ±10 kV three‐terminal DC distribution network, this paper sets up the medium‐voltage DCCB and formulates a fault protection strategy. Additionally, a simulation model
Lu Qu +7 more
openaire +2 more sources
A DC hybrid circuit breaker with ultra fast contact opening and integrated gate-commutated thyristors (IGCT) [PDF]
Air-magnetic circuit breakers are widely used for short-circuit protection in DC electric railways or industrial plants. The well-known drawbacks of these breakers are mainly a slow breaking action, a short lifetime and high maintenance costs due to the ...
Meyer, J.-M. +3 more
core +2 more sources
Analysis of topology and key technologies of a novel oscillatory DC circuit breaker
The oscillatory DC circuit breaker is an innovative DC circuit breaker technology that is expected to achieve fast interruption capability while reducing cost.
ZOU Hui +6 more
doaj +1 more source
A hybrid DC circuit breaker is the core protection equipment of a DC system, and its key parameters are critical to the products design and application, so the research on the influencing factors to such key parameters is of great significance to the ...
LUO Wenguang +4 more
doaj

