Results 81 to 90 of about 11,878 (206)
An adaptive reclosing strategy for high-voltage DC grids with mechanical DC circuit breakers
Yanxun Guo, Zhuang Xu, Xiaomei Yao
openaire +1 more source
Design description of the Schuchuli Village photovoltaic power system [PDF]
A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV ...
Delombard, R. +2 more
core +1 more source
Study of arc and magnetic field parameters under delayed breaking condition of DB-DC VCB
Taking the mechanical double-break DC vacuum circuit breaker (DB DC VCB) as the research object, the magnetic field and temperature field distribution between the breaks and the plasma characteristics under the working condition of gap difference caused ...
Chongyang Huang +4 more
doaj +1 more source
DC protection of a muti-terminal HVDC network featuring offshore wind farms [PDF]
A protection scheme for DC faults has been designed for a multi-terminal HVDC network used to transfer energy from three large offshore wind farms to shore.
Parker, Max +2 more
core +2 more sources
Environmental issues associated with the aviation industry are getting more attention as air traffic increases. Stringent standards are imposed for fuel consumption and pollution emissions for next-generation aircraft.
Muhammad Junaid +5 more
doaj +1 more source
Design considerations of series type hybrid circuit breaker (S‐HCB)
The series‐type direct current (DC) hybrid circuit breaker (S‐HCB) concept was previously reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid circuit breakers (HCB).
Mahmoud Alashi +5 more
doaj +1 more source
This paper presents a novel ultrafast DC circuit breaker concept based on a railgun actuator, designed for ultrafast charging stations operating at 800 V and delivering up to 640 kW. The proposed breaker achieves contact opening speeds exceeding 190 m/s,
Fermín Gómez de León +3 more
doaj +1 more source
This paper reports and analyzes the failure modes of a 1.2 kV low voltage (LV) solid-state dc circuit breaker (DCCB) over 3,000,000+ opening operations.
Yang Liu +4 more
doaj +1 more source
Apollo experience report: Command and service module controls and displays subsystem [PDF]
A review of the command and service module controls and displays subsystem is presented. The subsystem is described, and operational requirements, component history, problems and solutions, and conclusions and recommendations for the subsystem are ...
Olsen, A. B., Swint, R. J.
core +1 more source
Fast mechanical switches (FMSs) are critical components of DC circuit breakers (DCCBs), which require the switch action time to break to a sufficient distance within 3 ms in the DC line breaking scenario, while ensuring a long service life.
Puyi Cui +6 more
doaj +1 more source

