Results 111 to 120 of about 3,209,748 (299)
Analyzing mechanical and software solutions in their patents [PDF]
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.Includes bibliographical references (leaf 30).An analysis of patents was conducted in order to find the motivation and reasons behind selecting either a ...
Villarruel, Nicolas R
core
Compliant Pneumatic Feet with Real‐Time Stiffness Adaptation for Humanoid Locomotion
A compliant pneumatic foot with real‐time variable stiffness enables humanoid robots to adapt to changing terrains. Using onboard vision and pressure control, the foot modulates stiffness within each gait cycle, reducing impact forces and improving balance. The design, cast in soft silicone with embedded air chambers and Kevlar wrapping, offers durable,
Irene Frizza +3 more
wiley +1 more source
Background: In small children with left atrioventricular valve dysfunction, valve repair is preferred but some will require valve replacement. No prosthetic valve has growth potential, bioprostheses have poor durability, and mechanical prostheses have ...
Tayyaba Malik, MD +7 more
doaj +1 more source
Multiscale simulations of the aortic heart valve : applications in disease and surgery [PDF]
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.Includes bibliographical references (p. 136-148).This thesis presents mathematical models describing the mechanical behavior of the human aortic heart valve ...
Weinberg, Eli, 1979-
core
Durability of Soft Pneumatic Actuators: A Review and Benchmarking Protocol
Lack of durability is a key challenge hindering the broad scale adoption of soft pneumatic actuators (SPAs) in automation industries. This review provides a comprehensive overview of existing research on SPA durability, introduces a standardized durability benchmarking protocol to consolidate the testing of SPAs, and outlines promising directions for ...
Dickson Chiu Yu Wong +2 more
wiley +1 more source
Dysfunction of an On-X Heart Valve by Pannus
A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis.
Gomez, Elsa +3 more
core
Design of a gas force simulator for the MIT Electromechanical Valve Drive project [PDF]
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.Includes bibliographical references (leaf 29).The MIT electromechanical Valve Drive (EMVD) is a continuously variable valve actuation device for an automotive ...
Otten, James S. (James Stewart)
core
Modular, Textile‐Based Soft Robotic Grippers for Agricultural Produce Handling
This article introduces textile‐based pneumatic grippers that transform simple textiles into robust bending actuators. Detailed experiments uncover how cut geometry and fabric selection shape performance. Successful handling of fragile agricultural items showcases the potential of textile robotics for safe, scalable automation in food processing and ...
Zeyu Hou +4 more
wiley +1 more source
Detection of diesel engine valve clearance by acoustic emission. [PDF]
This paper investigated, using experimental method, the suitability of acoustic emission (AE) technique for the condition monitoring of diesel engine valve faults.
Gu, Fengshou +3 more
core +1 more source
Mechanical valve prosthesis is a valid option for aortic valve replacement in the elderly
Thromboembolism and hemorrhage related to anticoagulation remain a major concern in elderly patients with mechanical valves. Clinical results following isolated aortic valve replacement (AVR) with tilting disk and bileaflet prostheses in patients aged ...
Gregorio, Rosario +6 more