Results 161 to 170 of about 457 (219)
Bio-Plausible Multimodal Learning with Emerging Neuromorphic Devices. [PDF]
Sun H +7 more
europepmc +1 more source
Field Programmable Gate Array-Based Smart Switch to Avoid Inrush Current in PV Installations. [PDF]
Martínez-Figueroa GJ +2 more
europepmc +1 more source
MEMS Acoustic Sensors: Charting the Path from Research to Real-World Applications. [PDF]
Wang Q +5 more
europepmc +1 more source
Surface flashovers on metal-oxide varistor blocks
Extensive studies have been made of surface flashovers on varistor blocks using multipulse (MP currents which simulate multiple stroke lightning ground flashes. The MP results are compared with those obtained with single-pulse (SP) currents and with high temporary overvoltages (TOV) at 50Hz. The blocks used were mostly of 5kA rating as commonly used in
Darveniza Mat, Saha Tapan K.
openaire +3 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Simple Model of Metal Oxide Varistor for Pspice Simulation
IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems, 2004Metal oxide varistors (MOVs) are commonly used to suppress transients in many applications, such as industrial process measurement and control instrumentation, when exposed to electromagnetic interference. Varistors symmetrical, sharp breakdown characteristics enable them to provide transient suppression performance.
exaly +2 more sources
Recycling zinc oxide varistor blocks for electro‐active silicone composites
The recycling process toward the elimination of varistor wastes into new electro-active silicon composites has been investigated. We studied the dependence of the E-J characteristics on the aggregate content in the polymer matrix.
Renaud Metz, Said Tahir
exaly +2 more sources
Change of Varistor Voltage of Metal-oxide Varistor Influenced by Impulse Currents
IEEJ Transactions on Power and Energy, 2015Naoyuki Tsukamoto
exaly +2 more sources
A statistical analysis of metal oxide varistor current under distorted supply voltage conditions
: Leakage current monitoring is still relied upon when on-site condition assessment or stability analysis of metal oxide varistors is to be conducted. The non-availability of adequate testing equipment, capable of directly measuring resistive component ...
Pitshou N Bokoro, Ian R Jandrell
exaly +3 more sources
Varistor Voltage Behavior of Metal Oxide Varistors Stressed by Electromagnetic Pulse
2024 IEEE Joint International Symposium on Electromagnetic Compatibility, Signal & Power Integrity: EMC Japan / Asia-Pacific International Symposium on Electromagnetic Compatibility (EMC Japan/APEMC Okinawa)Kondo, Kensuke, Tsukamoto, Naoyuki
exaly +2 more sources
In this work, metal oxide varistor (MOV) design optimization and switching control in the main circuit breaker (MCB) branch of a progressively switched hybrid DC circuit breaker (DCCB) is presented. A progressively switched hybrid DCCB can achieve faster
Md Rifat Kaisar Rachi, Iqbal Husain
exaly +2 more sources