Impulse Life Evaluation Method of MOV Based on Weibull Distribution
The working life evaluation of metal oxide varistor (MOV) is always expected by MOV manufacturers and users. In Oct. 2019, the International Electrotechnical Commission (IEC) SC37B established a project team PT 61643–333 led by the author of this ...
Qibin Zhou +3 more
doaj +1 more source
Model Free Traveling Wave Based Fault Location Method for Series Compensated Transmission Line
Locating fault position in a series compensated transmission line is a difficult task due to the non-linear characteristics of the metal-oxide varistor which is present in the protection system of the compensator. In this paper, a model-free two-terminal
O. D. Naidu, Ashok Kumar Pradhan
doaj +1 more source
Measuring the energy handling capability of metal oxide varistors [PDF]
Metal oxide varistors are widely used in many power electronics circuits to protect against transient over voltages. Certain applications are very demanding on the energy handling capability of the varistors. This paper gives an overview of the failure modes of ZnO varistors and investigates their characteristics when subjected to repetitive current ...
Ahmed, M. M. R. +3 more
openaire +2 more sources
Two basic ways to realise DC circuit breakers
As a key element of the DC grid, the technology of DC circuit breakers (DCCBs) still have difficulty to be widely used due to its large cost and volume. This paper studies the basic principle and its realisation methods for DCCBs.
Zheng Xu +3 more
doaj +1 more source
Reduction Reactive Power and Collapse Voltage Using Series Capacitors Compensation in Sudden Change Loads of Transmission Lines [PDF]
The continuous increase of disturbances on the interconnected electric power system resulting in its inability to reliably meet demands. This paper presents an application of a series capacitor compensation in transmission line and shunt reactors ...
Hussein Thani Rishag
doaj +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
Metal oxide varistors (MOVs) are a type of resistor with significantly nonlinear current-voltage characteristics commonly used in power lines to protect against overvoltages.
Toni Gutknecht +4 more
doaj +1 more source
ABSTRACT This study examines the impact of aging on the electrical and structural properties of positive temperature coefficient of resistance (PTCR) ceramics. The presented study introduces a correlative scanning electron microscopy (SEM)/conductive atomic force microscopy (C‐AFM) approach enabling repeated, site‐specific characterization of ...
Kryštof Koller +4 more
wiley +1 more source
Strain‐Induced Redistribution of Point Defects in ZnO Nanoparticles
Powder compaction generates local strain effects in ZnO nanoparticles. This alters the abundance of intrinsic point defects and impacts the semiconductor's electronic structure. Such changes were analyzed by a combination of spectroscopy and density functional theory calculations and emphasize the importance of strain effects in the design and ...
Korbinian Aicher +4 more
wiley +1 more source
Influence of UHV GIL access on transient recovery voltage of circuit breaker
The access of ultra high voltage (UHV) gas-insulated transmission line (GIL) affects both the transient recovery voltage (TRV) amplitude and the rate of rise of TRV (RRRV) of circuit breakers,which may endanger the breaking capacity of circuit breakers ...
SUN Yi +5 more