Results 61 to 70 of about 2,366,283 (219)
Porous, rigid metal(III)-carboxylate metal-organic frameworks for the delivery of nitric oxide [PDF]
This work was supported by CNRS, EU through the ERC-2007-209241-BioMOFs ERC grant (J.F.E., P.H., C.S.). R.E.M. thanks the GEMI Fund and the E.P.S.R.C for funding.
Christian Serre +29 more
core +1 more source
The abnormal expansion associated with the simultaneous synthesis and sintering of Zn2SnO4 from ZnO and SnO2 is due to the reaction mechanism and correlated with the conversion. This phenomenon opens the way to manufacture porous ceramics without the addition of pore generators, simplifying the process, and especially the thermal treatment.
María José Orts +3 more
wiley +1 more source
The submodule in multilevel modular converters experiences a very fast transient overvoltage (VFTO) during switch operation of gas‐insulated switchgear, which also results in overvoltage on power devices, such as thyristors and insulated gate bipolar ...
Hong Shen +7 more
doaj +1 more source
Series-compensated transmission lines (SCTLs) are increasingly preferred for transmitting bulk amounts of electricity generated from the present-day large-scale wind farm to the utility grid due to several technical and economic benefits. However, when a
M. S. Prabhu +4 more
doaj +1 more source
This paper presents a calculation model for the nonlinear characteristics of varistors based on a basic conductive mechanism, and it has been verified through experiments. The mechanism of the barrier's effect on electrical performance has been obtained.
Zhengzheng Fu +7 more
wiley +1 more source
This study comparatively assesses lightning‐overvoltage propagation to the transformer high‐voltage terminal and hydrogenerator busbar of a hydropower plant under prescribed lightning‐current injection and selected nonideal conditions of a station‐side metal‐oxide arrester.
Jiachen Zhang +9 more
wiley +1 more source
Metal-oxide surge arresters (MOSAs) are critical devices for overvoltage protection in power systems, and the aging characteristics of their zinc oxide (ZnO) varistors under impulse and power-frequency voltages exhibit significant differences.
Yongqiang Fan +7 more
doaj +1 more source
A new evolutionary search algorithm based on improved Particle Swarm Optimisation (PSO) is introduced in this study to estimate the phasor. The performance has been evaluated through extensive simulations considering transient components, harmonics, and frequency changes in noiseless and noisy conditions.
Seyedeh Mina Abed Shiadeh +2 more
wiley +1 more source
Abstract Microstructure homogeneity and grain size reduction are needed to ensure the current uniformity and reliability required in metal oxide varistors for DC circuit breakers. Cold sintering (CS)–a low‐temperature digestive liquid and high‐pressure densification process–has previously shown reduced grain growth, but it is not clear how the lower ...
Kayla Y. Chuong +5 more
wiley +1 more source
Performance comparison between Metal Oxide Varistor and Gas Discharge Tube against transient overvoltage due to lightning strike: article [PDF]
This project presents the comparison of the performance protection devices of transient overvoltage due to lightning strike. There were two protection devices compared in this project which is Metal Oxide Varistor (MOV) and Gas Discharge Tube (GDT ...
Johari, Dalina, Ajut, Lawrence
core

