Results 71 to 80 of about 2,517,738 (175)

Superior performing nano‐enabled metal oxide varistors [PDF]

open access: yesInternational Journal of Ceramic Engineering & Science, 2019
AbstractCommercial metal oxide varistor devices are subject to nonuniformity, defects and coarse grain size, low working voltage, high leakage current, and mechanical cracking issues. This work tempted to make use of nanopowders and alternative sintering processes to achieve uniform microstructure and superior varistor performance.
openaire   +1 more source

A Bi‐GRU–Based Protection Scheme for Reliable Fault Identification in Series‐Compensated Transmission Lines

open access: yesIET Smart Grid, Volume 9, Issue 1, January/December 2026.
This paper presents a deep Bidirectional Gated Recurrent Unit (Bi‐GRU)‐based protection scheme for series‐compensated transmission lines using only local voltage and current measurements. The proposed method extracts fundamental‐frequency phasors through discrete Fourier transform and is trained on a comprehensive dataset covering various compensation ...
Majid Khezerloo   +2 more
wiley   +1 more source

Temperature monitoring of metal oxide surge arresters [PDF]

open access: yes, 2013
Varistor overtemperature above the ambient is an important state parameter of metal oxide surge arresters. The temperature monitoring using passive SAW sensors enables realisation of a surge counter function, an energy monitor, monitoring of electrical ...
Hinrichsen, V., Chrzan, K L
core  

The Effects of Electrical Degradation on the Microstructure of Metal Oxide Varistor [PDF]

open access: yes, 2001
In this paper, the findings from systematic experiments with the purpose to determine the degradation effect of single and multiple current pulses on the microstructure of the Metal Oxide (MO) varistor are described. Six distribution class varistors from
Saha, Tapan K.   +2 more
core   +1 more source

Determining the effect of bismuth oxide on the microstructure and electrical response of cold‐sintered ZnO varistors

open access: yesJournal of the American Ceramic Society, Volume 109, Issue 1, January 2026.
Abstract Microstructure homogeneity and grain size reduction are needed to ensure the current uniformity and reliability required in metal oxide varistors for DC circuit breakers. Cold sintering (CS)–a low‐temperature digestive liquid and high‐pressure densification process–has previously shown reduced grain growth, but it is not clear how the lower ...
Kayla Y. Chuong   +5 more
wiley   +1 more source

Back Flash Overvoltage Damages All DC/AC Converters in Photovoltaic Systems

open access: yesIEEE Access
This research addresses real faults in photovoltaic (PV) systems in Cuba, as these faults result in damage to all converters, whether in operation or not, when atmospheric discharge strikes nearby.
Osmel Perez Baluja   +4 more
doaj   +1 more source

Metal Oxide Surge Arresters under Nonsinusoidal Voltage Stresses [PDF]

open access: yes, 2019
Tato práce se zabývá vlivem vysokofrekvenčního napěťového zkreslení na omezovače přepětí pro vysokonapěťové aplikace. V rešeršní části jsou nejprve rozebrány základní typy svodičů používaných v soustavách vysokého napětí.
Ivan Chromeček
core  

Zno varistor of low-temperature sintering ability

open access: yes, 2011
[[abstract]]Zinc oxide (ZnO) varistors containing vanadium oxide as the principal additive and one or more cobalt oxides and/or manganese oxides additives exhibit excellent nonlinear current-voltage characteristics.
Wu, Tai-Bor;Tsai, Jyh-Kuang
core  

Performance comparison between Metal Oxide Varistor and Gas Discharge Tube against transient overvoltage due to lightning strike [PDF]

open access: yes, 2014
This project presents the comparison of the performance of transient overvoltage due to lightning strike. There were two protection devices compared in this project which is Metal Oxide Varistor (MOV) and Gas Discharge Tube (GDT).
Ajut, Lawrence
core  

Stability of Metal-Oxide Varistor Characteristics in Exploitation Conditions

open access: yesActa Physica Polonica A, 2009
Wide-spread use of metal–oxide varistors for non-linearity over-voltage protection results in a variety of possible working conditions. It is therefore essential to have a thorough insight into their reliability in various exploitation environments.
Lončar, Boris B.   +3 more
openaire   +3 more sources

Home - About - Disclaimer - Privacy