Results 61 to 70 of about 236 (182)

A Device for Investigating the AC Characteristics of Metal Oxide Varistors

open access: yesIET Power Electronics
In recent years, the AC characteristics of metal oxide varistors have attracted growing research interest. This study presents an insulated‐gate bipolar transistor‐based device designed to address the limitations of existing power supply systems, which ...
Xinyan Xiao, Lanjun Yang, Yonggang Yue
doaj   +1 more source

Advancements in wearable heart sounds devices for the monitoring of cardiovascular diseases

open access: yesSmartMat, Volume 6, Issue 1, February 2025.
This article presents the recent advancements in wearable and flexible heart sound devices, focusing on their mechanics, types of sensors, flexible sensing materials, and prospective denoising techniques. Furthermore, the potential applications of heart sounds for the monitoring of cardiovascular diseases are reviewed as well along with its future ...
Rafi u Shan Ahmad   +5 more
wiley   +1 more source

Mechanism and suppression of breaking overvoltage of DC circuit breakers

open access: yesHigh Voltage, Volume 10, Issue 1, Page 32-46, February 2025.
Abstract The occurrence of breaking overvoltage in a DC circuit breaker (DCCB) poses a potential threat to the safe operation of a DC grid. Based on the structure of the ±10 kV three‐terminal DC distribution network, this paper sets up the medium‐voltage DCCB and formulates a fault protection strategy.
Lu Qu   +7 more
wiley   +1 more source

Lightning protection for power transformers of Aqaba Thermal Power Station

open access: yesArchives of Electrical Engineering, 2020
In this paper, a study of the lightning phenomenon and its harmful effect on Aqaba Thermal Power Station (ATPS), located in the south-western border of Jordan, is presented using the Electromagnetic Transients Program – Alternative Transients Program ...
Wael Fawzi Abu Shehab   +2 more
doaj   +1 more source

Research on influence of double energy absorptions on dynamic volt‐ampere characteristics of metal oxide varistors

open access: yesHigh Voltage, Volume 10, Issue 1, Page 78-87, February 2025.
Abstract Metal oxide varistors (MOVs) are extensively employed in DC circuit breakers (DCCBs) to suppress overvoltage, dissipate energy and build up voltage after interruption. Despite their widespread use, the performance of MOVs under short‐time, double energy absorption conditions is not well understood, posing a challenge to their application in ...
Chen Long   +5 more
wiley   +1 more source

Influence of Y–Bi–Co oxide doping on electrical performance of ZnO varistors based on simulation analysis

open access: yesInternational Journal of Ceramic Engineering &Science, Volume 7, Issue 1, January 2025.
Simulation methods were used to help reveal the effect mechanism of Y, Bi, and Co dopants on ZnO varistors. It provides an important theoretical basis for the development of high‐performance varistor. Abstract ZnO varistors doped with Y2O3${\rm Y}_2{\rm O}_3$, Bi2O3${\rm Bi}_2{\rm O}_3$, and Co2O3${\rm Co}_2{\rm O}_3$ were analyzed for electrical ...
Zhengzheng Fu   +7 more
wiley   +1 more source

High‐Current Cryogenic DC Solid‐State Circuit Breaker for Electric Aircraft

open access: yesIET Electric Power Applications, Volume 19, Issue 1, January/December 2025.
Cryogenic and superconducting technologies have great potential to significantly enhance the power density and efficiency of electric propulsion aircraft. This paper presents the design of a 300 V/1700 A DC solid‐state circuit breaker (SSCB) operating at cryogenic temperatures.
Zhongying Wang   +8 more
wiley   +1 more source

Back Flash Overvoltage Damages All DC/AC Converters in Photovoltaic Systems

open access: yesIEEE Access
This research addresses real faults in photovoltaic (PV) systems in Cuba, as these faults result in damage to all converters, whether in operation or not, when atmospheric discharge strikes nearby.
Osmel Perez Baluja   +4 more
doaj   +1 more source

MOV型SPD在交直流电压下的热量累积对比分析

open access: yesDianci bileiqi, 2011
MOV型SPD在运行时,一些因素会使MOV启动后的电流过大,电流发热量超出MOV热容量就会使SPD失效。国家标准中热稳定实验考查的就是MOV对于这种热量累积的耐受程度。对国家标准中关于MOV(Metal Oxide Varistor)型SPD(Surge Protective Device)的热稳定性判断条件进行试验和分析,对比了直流和交流电压两种情况下的热量累积并设计试验。把直流电和交流电热累积统一到"热阻"的概念,试验表明,直流电造成的SPD发热量比交流电造成的SPD发热量大10%。
杨天琦, 王振会, 朱传林, 孙涌
doaj  

Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis. [PDF]

open access: yesSensors (Basel), 2023
Zacarias TG   +9 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy