Retrieval of a Micra transcatheter pacing system in a heart with a preexisting lead

open access: yesIndian Pacing and Electrophysiology Journal, 2018
We report the case of a 74-year-old man with a previously implanted pacemaker lead. He had undergone Medtronic™ Micra Transcatheter Pacing System (TPS, Medtronic plc, MN, USA) implantation because of lead fracture.
Junji Morita   +5 more
doaj   +7 more sources

Implantation of the Micra transcatheter pacing system: A single center North India experience

open access: yesIndian Pacing and Electrophysiology Journal, 2021
Background: The leadless pacemaking transcatheter system, Micra, is a miniaturized, single-chamber pacemaker system. We report herein our experience with implantation of the Micra TPS system.
Viveka Kumar   +4 more
doaj   +5 more sources

Successful percutaneous retrieval of a micra transcatheter pacing system at 8 weeks after implantation [PDF]

open access: yesJournal of Arrhythmia, 2018
An 86‐year‐old woman suffering from repeated methicillin‐resistant Staphylococcus aureus (MRSA) bacteremia underwent percutaneous lead extraction using an excimer laser. Since negative blood cultures were confirmed three times after lead extraction under
Masatsugu Nozoe   +6 more
doaj   +4 more sources

Successful Retrieval of a 4-Year-Old Micra Transcatheter Pacemaker System in a Patient With Leadless Biventricular Pacing Therapy

open access: yesJACC: Case Reports, 2020
This is the first report of the management of a patient with cardiac resynchronization therapy using leadless biventricular pacing. Successful retrieval of a 4-year-old Micra transcatheter pacing system (TPS) and reimplantation of a new Micra TPS ...
Kentaro Minami, MD   +10 more
doaj   +5 more sources

Extraction of a Micra Transcatheter Pacing System: First-in-human experience [PDF]

open access: yesHeartRhythm Case Reports, 2016
Saima Karim, DO   +4 more
doaj   +5 more sources

Pericardial effusion caused by accidently placing a Micra transcatheter pacing system into the coronary sinus [PDF]

open access: yesBMC Cardiovascular Disorders, 2021
Background Leadless pacemaker has been acknowledged as a promising pacing strategy to prevent pocket and lead-related complications. Although rare, cardiac perforation remains a major safety concern for implantation of Micra transcatheter pacing system ...
Xueying Chen   +4 more
doaj   +4 more sources

An Intraoperative Fluoroscopic Predictor of Successful Micra Implantation on the Right Ventricular Mid‐Septum

open access: yesJournal of Arrhythmia
Background The Micra transcatheter pacing system has been adopted globally. However, the procedural parameters for safe Micra implantation on the ventricular wall, particularly in the mid‐septum, remain unknown.
Misun Pak   +3 more
doaj   +2 more sources

Implantation of a leadless pacemaker as a promising solution for patients with arythmia – current state of knowledge

open access: yesJournal of Education, Health and Sport, 2023
Introduction: In cardiac electrotherapy, new solutions are constantly sought to minimise the invasiveness of methods used so far and reduce the risk of complications.
Anna Maciąg   +9 more
doaj   +1 more source

Assessing safety of leadless pacemaker (MICRA) at various implantation sites and its impact on paced QRS in Indian population

open access: yesIndian Heart Journal, 2020
Background: In this study we report our experience in implanting MICRA TPS (transcatheter pacing system) at various RV sites; observing its safety, and impact on paced QRS in Indian population.
Prafull Sharma   +3 more
doaj   +1 more source

Leadless pacemaker through tricuspid bioprosthetic valve: Early experience

open access: yesJournal of Arrhythmia, 2021
Background Leadless pacemaker (LP) therapy has been proved effective in cases where traditional transvenous right pacing (TRP) failed. TRP through a bioprosthetic tricuspid valve (BTV) has always been considered an unpreferable solution because of ...
Giovanni Morani   +3 more
doaj   +1 more source