Local versus general anesthesia for transcatheter aortic valve implantation (TAVR)- systematic review and meta-analysis [PDF]
The hypothesis of this study was that local anesthesia with monitored anesthesia care (MAC) is not harmful in comparison to general anesthesia (GA) for patients undergoing Transcatheter Aortic Valve Implantation (TAVR).TAVR is a rapidly spreading ...
Webb, J +21 more
core +2 more sources
BACKGROUND: With its steerable transcatheter delivery system, the Micra can be deployed in nonapical positions within the right ventricle, potentially allowing reduction of the paced QRS width.
Vandenberk, Bert +11 more
core +1 more source
Transcatheter Aortic Valve Implantation in Dialysis Patients [PDF]
Background/Aims: Transcatheter aortic valve implantation (TAVI) has emerged as a new therapeutic option for high-risk patients. However, dialysis patients were excluded from all previous studies.
Wessely, Matthias +6 more
core +1 more source
ABSTRACT Background Disparities in invasive cardiovascular care and outcomes in rural and urban hospitals across the United States have been reported. However, studies investigating disparities regarding leadless pacemaker outcomes and complications based on hospital location are lacking.
Amanda Nguyen +15 more
wiley +1 more source
Retrieval of a dislodged leadless pacemaker: An example of the double‐snare technique
A video demonstration presents the retrieval of a dislodged leadless pacemaker using the double‐snare technique. Sharing troubleshooting strategies in such cases is clinically important for managing rare pacemaker complications.
Momo Taira +4 more
wiley +1 more source
Updated Performance of the Micra Transcatheter Pacemaker in the Real-World Setting : a Comparison to the Investigational Study and a Transvenous Historical Control [PDF]
BACKGROUND: Early results of the Micra Investigational Device Exemption (IDE) study and Micra Post-Approval Registry (PAR) demonstrated excellent safety and efficacy performance; however, intermediate-term results across a large patient population in ...
El-Chami, Mikhael F. +36 more
core +1 more source
To prevent cardiac tamponade caused by catheter tip slippage during the retraction of the protective sleeve in Aveir VR implantation, it is crucial to carefully evaluate not only the bulge of the protective sleeve but also the shape of the system's shaft using fluoroscopic imaging.
Masanori Matsuo +4 more
wiley +1 more source
Transcatheter aortic-valve replacement for inoperable severe aortic stenosis. [PDF]
BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is the recommended therapy for patients with severe aortic stenosis who are not suitable candidates for surgery. The outcomes beyond 1 year in such patients are not known.
Makkar, Raj R +26 more
core +1 more source
Strategies to improve AV synchrony in patients with a Micra AV leadless pacemaker. [PDF]
The second generation of transcatheter pacing systems, called Micra AV, can provide atrio-ventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction.
De Asmundis, Carlo +13 more
core +3 more sources
When we recapture the Micra system, we capture the body by pulling the tether attached to the delivery catheter and retrieve it, but sometimes it is difficult, and the Micra is dislodged and fixed in the tricuspid valve annulus. Using a single snare catheter from the superior vena cava and pushing the tines changes the orientation of the device and ...
Keisuke Kojima +4 more
wiley +1 more source