Results 41 to 50 of about 3,510,056 (188)
To report the relative efficacy of combining phacoemulsification with a Schlemm's canal microstent (Phaco/Hydrus) or dual blade trabecular excision (Phaco/KDB).Retrospective study.One hundred and thirty-one eyes of 131 patients who underwent Phaco/Hydrus or Phaco/KDB procedures from January 2016 to July 2021 at a tertiary care center were included and ...
B. Oberfeld +5 more
openaire +2 more sources
Minimally Invasive Glaucoma Surgery and CyPass® Micro-Stent—A New Era in Glaucoma Surgery
In the largest randomized clinical trial to date on a minimally invasive glaucoma surgery device, the CyPassR Micro-Stent was able to lower intraocular pressure (IOP) more than was modern cataract surgery (phacoemulsification and intraocular lens ...
Sameh Mosaed, null null
core +1 more source
Minimally Invasive Glaucoma Surgery [PDF]
This book covers all aspects of minimally invasive glaucoma surgery (MIGS) and provides detailed information on each MIGS device, including its mechanism of action; patient selection; implantation techniques; post-operative management; and a review of ...
Barton, K, Sng, CCA
core +1 more source
Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods:
Gloria Gambini +12 more
doaj +1 more source
Purpose. To assess safety and effectiveness of calibrated cyclodialysis ab interno involving implantation of a non-absorbable collagen implant in the suprauveal space in decreasing IOP in glaucoma patients.Methods. Forty-three patients (43 eyes; 16 male and 27 females; average age — 70.4 ± 10.0 years) were included in this pilot study.
V. Kumar +2 more
openaire +4 more sources
Premium Intraocular Lens Selection in Patients With Glaucoma: A Clinical Review
ABSTRACT Glaucoma frequently coexists with cataract, but glaucomatous functional loss, ocular‐surface disease, anatomical abnormalities, and treatment‐related refractive variability may reduce tolerance of premium intraocular lenses. This narrative review critically appraises evidence relevant to lens selection in glaucoma. Central visual‐field status,
Zhihao Liu +3 more
wiley +1 more source
3D‐Printed Corneal Substitutes: Materials, Fabrication, and Preclinical Progress
Successful clinical translation of 3D‐printed corneal substitutes relies on the interplay between the bioink properties, cellular component, and the fabrication process. These factors influence the critical properties of the construct, including optical transparency, mechanical stability, suture retention, that ultimately govern long‐term stromal ...
Shadi Moshayedi +4 more
wiley +1 more source
This review highlights recent advances in engineering messenger RNA (mRNA)‐lipid nanoparticles (LNPs) to cross the ageing blood–brain barrier and target neurodegenerative diseases. It outlines design principles, delivery routes, and translational challenges, charting a roadmap towards clinical application of mRNA‐LNP therapeutics for neurodegenerative ...
Abdel Ali Belaidi +5 more
wiley +1 more source
ABSTRACT The 2026 Asia Pacific Heart Rhythm Society (APHRS) Guidelines represent the first comprehensive APHRS guidelines dedicated to the management of atrial fibrillation (AF) and comprise four parts covering epidemiology, detection/screening and integrated care; stroke prevention; rate and rhythm control; and lifestyle risk factor and comorbidity ...
Tze‐Fan Chao +15 more
wiley +1 more source
Background The short- and medium-term outcomes of iStent have been extensively studied; however, only few studies have investigated its long-term outcomes.
Ali Salimi +2 more
doaj +1 more source

