Results 61 to 70 of about 3,510,056 (188)
Target IOP as a measure of glaucoma surgery efficacy
There are numerous criteria of glaucoma surgery efficacy. Among them, IOP level is of special importance. The development of tolerant and target IOP concepts as well as IOP tolerability issue are reviewed below.
S. Yu. Petrov
doaj +3 more sources
ABSTRACT Several benign, inflammatory and malignant lesions can present as iris or anterior chamber masses, including iris naevi, cysts, adenomas, leiomyomas, nodules, vascular tumours, melanomas, metastases, as well as iris and pigment epithelium adenocarcinomas. Fortunately, benign iris lesions are much more common than malignant tumours and many can
Charles N. J. McGhee +3 more
wiley +1 more source
A thermo‐responsive poly(2‐oxazoline)‐based injectable formulation is developed to modulate intraocular pressure (IOP) in both normal and hypotonic eyes. By adjusting the PEG content, the aggregation behavior is finely tuned, enabling IOP elevation without long‐term deposition.
Yuji Tanaka +2 more
wiley +1 more source
JD Sheppard,1 IP Singh21Department of Ophthalmology, Eastern Virginia Medical School, Norfolk, VA, USA; 2Department of Glaucoma, The Eye Centers of Racine & Kenosha, Racine, WI, USAPurpose: With the increasing use of minimally invasive surgical ...
Sheppard JD, Singh IP
doaj
Regina Cele Silveira Seixas,1 Marcos Balbino,2 Alberto Basile Neto,3 Amanda de Alcantara Almeida Costa,4 Marcelo Lopes da Silva Jordão,5 Heloisa Helena Abil Russ6 1HCloe Oftalmologia Especializada, Universidade Federal de São Paulo, S ...
Silveira Seixas RC +5 more
doaj
Catechol‐functionalized cellulose hydrogels are developed as injectable, bioadhesive platforms for retinal neuroprotection. The hydrogels exhibit tunable rheological and mechanical properties, strong tissue adhesion, and sustained antioxidative activity.
Kai‐Hsiang Chang +4 more
wiley +1 more source
Fiberoptic 6-DOF Force-Torque-Sensing for Haptic Feedback in Minimally Invasive Robotic Surgery [PDF]
In minimally invasive robotic surgery long and slender instruments are introduced into the body of the patient through small incisions or natural orifices.
Hirzinger, Gerd +4 more
core
iStent trabecular micro-bypass stent for open-angle glaucoma
Kim Le, Hady Saheb Department of Ophthalmology, McGill University, Montreal, QC, Canada Abstract: Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other
Le K, Saheb H
doaj
Modern trends in the treatment of glaucoma
In nearly all Russian regions, glaucoma ranks first among the causes of disability due to ophthalmic pathology, which is in line with global trends of glaucoma incidence growth and its leading position among the causes of irreversible blindness ...
S. Yu. Petrov +2 more
doaj +1 more source
From Flexible to Conformable Pressure Sensors: Mechanisms, Materials, and Biomedical Applications
This review highlights recent progress, challenges and future opportunities in pressure sensing for advanced biomedical applications. We summarize key transduction mechanisms and emerging material strategies, discuss representative wearable and implantable applications for continuous physiological monitoring and provide a focused perspective on barrier
Rishabh B. Mishra +2 more
wiley +1 more source