Results 61 to 70 of about 778,156 (254)

Calibration of an array of voltammetric microelectrodes [PDF]

open access: yesAnalytica Chimica Acta, 1996
The calibration of a voltammetric sensor consisting of an array of individually modified electrodes is described. Linear calibration methods do not yield good results because of the inherent non-linear nature of the data. Neural networks can in principle model such dependencies, but their success is crucially dependent on the representation of the data.
Wehrens, R., van der Linden, W.E.
openaire   +2 more sources

Characterization of microelectrode array of dielectrophoretic microfluidic device

open access: yes, 2016
This paper presents the characterization of angled microelectrode array as dielectrophoretic microfluidic device for the continuous flow-through separation of particles.
Abdul Halin, Izhal   +2 more
core   +1 more source

Friend, Not Foe: Lowered Tissue Reactivity to Long‐Term Polyimide Implants

open access: yesAdvanced Science, EarlyView.
The choice of optimal neural probe designs remains a major challenge in the field of neurotechnology. This study investigated the biocompatibility of several probe variations, including material, thickness, width, and implantation strategy. It highlights the clear advantage of soft polyimide probes over stiff silicon probes for better device ...
Corinne Orlemann   +11 more
wiley   +1 more source

Electrokinetically Control Flow Mixing in Microfluidic Chip Utilizing Microelectrode Based on Indium Tin Oxide

open access: yesMATEC Web of Conferences, 2017
In order to blend the liquid in the microfluidic chip adequately, this paper presented a novel mixing scheme in which the species streams was mixed via the application of Lorenz chaotic system algorithm to three pair of parallel electrodes mounted on the
Lv Tianyuan   +4 more
doaj   +1 more source

Shape-Dependent Velocity Based Droplet Routing on MEDA Biochips

open access: yesIEEE Access, 2022
Digital microfluidic biochip (DMFB) has attracted attention in the biochemical and medical industries. In particular, a microelectrode dot array (MEDA) biochip, which is composed of a two-dimensional microelectrode array, enables to realize fine-grained ...
Chiharu Shiro   +5 more
doaj   +1 more source

Harnessing Phase Separation for the Development of High‐Performance Hydrogels

open access: yesAdvanced Science, EarlyView.
ABSTRACT Hydrogels are indispensable for the development of next‐generation bioelectronics, soft robotics, and biomedical devices, where their mechanical properties determine performance and reliability. Among strategies to enhance hydrogel mechanics, phase separation enables controlled heterogeneity resulting in gel networks that are reinforced by ...
Yue Shao   +3 more
wiley   +1 more source

Electrochemical Characterisation and Application of Multi Microelectrode Array Devices to Biological Electrochemistry

open access: yesSensors, 2001
A new design for microelectrode array (MEA) devices fabricated by semiconductor-processing techniques is presented. The microelectrode surfaces consist of gold and are surrounded by an insulating silicon nitride layer.
William S. McIntire   +4 more
doaj   +1 more source

Microelectrode Array based Functional Testing of Pancreatic Islet Cells

open access: yesMicromachines, 2020
Electrophysiological techniques to characterize the functionality of islets of Langerhans have been limited to short-term, one-time recordings such as a patch clamp recording.
Ahmad Alassaf   +3 more
doaj   +1 more source

Soft Microelectrode Linear Array for Scanning Electrochemical Microscopy [PDF]

open access: yes, 2016
A linear array of eight individual addressable microelectrodes has been developed in order to perform high-throughput scanning electrochemical microscopy (SECM) imaging of large sample areas in contact regime.
Fernando Cortés-Salazar (1615348)   +4 more
core   +2 more sources

A very large-scale microelectrode array for cellular-resolution electrophysiology

open access: yesNature Communications, 2017
Large electronics limit low-noise, non-invasive electrophysiological measurements to a thousand simultaneously recording channels. Here the authors build an array of 65k simultaneously recording and stimulating electrodes and use it to sort and classify ...
David Tsai   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy