Results 51 to 60 of about 35,850 (270)
Double‐Sided Conformable Piezoelectric Force Sensor with Enhanced Performance and Bending Correction
This work addresses the challenge of measuring low forces on soft surfaces. An innovative conformable piezoelectric force sensor is presented. The use of a highly flexible TPU substrate enables a tenfold increase in the sensor's sensitivity to compression while a double‐sided structure prevents the signal from being disturbed by bending due to ...
Joseph Faudou+6 more
wiley +1 more source
Mitral valve repair for extreme billowing and prolapsing valveCentral MessagePerspective
Objectives: We describe our method and results of mitral valve repair up to 20 years in a defined group of patients with mitral regurgitation caused by an extreme billowing and prolapsing valve.
Hitoshi Kasegawa, MD+4 more
doaj
Phenotypic Expansion of Knobloch Syndrome Type 2 in an Individual With a De Novo PAK2 Variant
ABSTRACT P21‐activated kinase 2 (PAK2) is a serine/threonine kinase essential for a variety of cellular processes including signal transduction, cellular survival, proliferation, and migration. A recent report proposed monoallelic PAK2 variants cause Knobloch syndrome type 2 (KNO2)—a developmental disorder primarily characterized by ocular anomalies ...
Elizabeth A. Werren+10 more
wiley +1 more source
Sydenham's chorea (SC) is the neurological manifestation associated with acute rheumatic fever (ARF), triggered by a group A streptococcal (GAS) infection. Anti‐GAS antibodies cross‐reacting with tissue proteins are implicated in the development of neurological changes. In this study, using an animal model, we demonstrate that a compromised blood–brain
Rukshan Ahamed Mohamed Rafeek+8 more
wiley +1 more source
Transcatheter mitral valve repair for primary mitral regurgitation
The landscape of transcatheter mitral valve repair devices continues to expand, with many technologies undergoing investigation in patients with primary mitral regurgitation (MR).
Rowa H. Attar+2 more
doaj +1 more source
Automatic Time‐Resolved Cardiovascular Segmentation of 4D Flow MRI Using Deep Learning
Background Segmenting the whole heart over the cardiac cycle in 4D flow MRI is a challenging and time‐consuming process, as there is considerable motion and limited contrast between blood and tissue. Purpose To develop and evaluate a deep learning‐based segmentation method to automatically segment the cardiac chambers and great thoracic vessels from 4D
Mariana Bustamante+4 more
wiley +1 more source
Hammock mitral valve: A rare case report
Congenital mitral stenosis is a relatively rare disorder comprising 0.2% of all congenital heart defects. Hammock mitral valve producing severe mitral stenosis is a rare variant of congenital mitral stenosis.
Veeresh F. Manvi+5 more
doaj +1 more source
Twenty-Year Experience with Surgery for Native and Prosthetic Mitral Valve Endocarditis
Background and Objectives: To evaluate the early and long-term results of surgical treatment of isolated mitral native and prosthetic valve infective endocarditis.
Antonella Galeone+7 more
doaj +1 more source
Objective To determine the optimal anticoagulation intensity of warfarin in a South‐East Asian population with moderate‐to‐severe rheumatic mitral stenosis. Methods A multicentre, retrospective study examined patients with rheumatic mitral stenosis who had not undergone valve replacement or repair and required long‐term warfarin therapy at two ...
Punyawee Puchsaka+6 more
wiley +1 more source
Introduction:Mitral valve repair is the treatment of choice to correct mitral insufficiency, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce.Objective:To analyze mitral ...
Marco Antônio Vieira Guedes+6 more
doaj +1 more source