Results 71 to 80 of about 1,743,769 (298)
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.
Lisa Crusius +9 more
wiley +1 more source
Evaluation of Echocardiography Results after Severe Mitral Valve Regurgitation Repair Surgery
BACKGROUND AND OBJECTIVE: Severe mitral valve regurgitation, which occurs primarily or secondary to various cardiovascular diseases, has undergone surgery and valve replacement and artificial valve insertion from several years ago.
MT Salehi Omran +2 more
doaj
Percutaneous treatment of mitral regurgitation recurrence after mitral valve surgery
Mitral regurgitation is one of the most common cardiac valve disorders worldwide and the second most frequent indication of cardiac surgery for heart valve disease.
Benito-González, Tomás +6 more
core
ABSTRACT Background Transcatheter closure (TCC) of sinus venosus defects (SVD) using balloon‐expandable covered stents is an emerging alternative to surgery. ZephyrCS (Sahajanand Laser Technologies, Gandhinagar, India) is available in long lengths to suit SVD closure.
Pramod Sagar +3 more
wiley +1 more source
Minimally invasive techniques in cardiac surgery gained popularity due to many advantages like less postoperative pain, minimal blood loss, less hospital stay, less cost.
E. Nourelden +3 more
doaj +1 more source
Port-Access Mitral Valve Surgery-An Evolution of Technique.
Port-access mitral valve surgery has been around since 1995; and many variations upon the technique have been developed. Since 1996, we have performed more than 2500 port-access mitral valve surgeries, and thus gained a substantial experience.
Barac, Yaron D, Glower, Donald D
core +1 more source
Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery
ABSTRACT Single leaflet device attachment (SLDA) after mitral transcatheter valve edge‐to‐edge repair (M‐TEER) has been reported in up to 5% of patients. However, complete embolization of the M‐TEER device is exceedingly rare. Device retrievals in all previously reported cases were completed by vascular surgery cut down at the end. In this case, we are
Seyed Hossein Aalaei‐Andabili +2 more
wiley +1 more source
ABSTRACT The case regards a 73‐year‐old male who was referred for consideration of percutaneous left atrial appendage closure. His left atrial appendage was ligated during prior mitral valve surgery, but was noted to be patent on a recent transesophageal echocardiography. An Amulet device was selected based on CT planning.
Zach Rozenbaum, Eric Gnall
wiley +1 more source
Tricuspid Valve Repair after Previous Mitral Valve Surgery
Tricuspid valve (TV) regurgitation in patients after previous mitral valve surgery is usually a secondary failure and conditioned by a long-lasting left-sided valve failure.
Martin Haensig +4 more
core +1 more source
Suture map for endoscopic mitral valve replacement
Mitral valve replacement using an endoscopic approach is an advanced skilled procedure. The purpose of creating the suture map for mitral valve replacement is to allow placement of sutures with the least tissue manipulation.
Sardari Nia, Peyman, Hamid, Umar Imran
core +1 more source

